Chapter 4
Troubleshooting Using RAIDar
63
Correcting Enclosure IDs
When installing a system with drive enclosures attached, the enclosure IDs might
differ from the physical cabling order. This is because the controller might have
been previously attached to some of the same enclosures and it attempts to preserve
the previous enclosure IDs if possible. To correct this condition, you can perform a
rescan.
To rescan, as an Advanced Manage user:
1. Verify that both controllers are up.
2. Select Manage > Utilities > Disk Drive Utilities > Rescan.
In the Rescan For Devices panel, click Rescan.
Problems After Power-On or Restart
After powering on the storage system or restarting the MC or SC, the processors
take about 45 seconds to boot up, and the system takes an additional minute or more
to become fully functional and able to process commands from RAIDar or the CLI.
The time to become fully functional depends on many factors such as the number of
enclosures, the number of disk drives, the number of virtual disks, and the amount
of I/O running at the time of the restart. During this time, some RAIDar or CLI
commands might fail and some RAIDar pages may not be available. If this occurs,
wait a few minutes and try again.