R-Can Sterilight SC1 Скачать руководство пользователя страница 1

Owner’s Manual

Installation, Operation and Maintenance

sc1, sc2.5, sc4,

sc1/2, sc2.5/2, sc4/2

425 Clair Road West  P.O. Box 1719

Guelph, ON  N1L 1R1  Canada

t. 519 763 1032  f. 519 763 5069

e. [email protected]  i.  www.r-can.com

Manufactured in Canada by:

EPA# 57987-CN-001

January 2008

P/N 520074

Содержание Sterilight SC1

Страница 1: ...and Maintenance sc1 sc2 5 sc4 sc1 2 sc2 5 2 sc4 2 425 Clair Road West P O Box 1719 Guelph ON N1L 1R1 Canada t 519 763 1032 f 519 763 5069 e water r can com i www r can com Manufactured in Canada by EP...

Страница 2: ...ronmentally Friendly lamps throughout our entire product offering Low mercury Hg technology provides lamps with less than 10 mg of mercury including our amalgam lamps up to 70 less mercury than the co...

Страница 3: ...ns 2 Water Chemistry 3 Installing Your UV Disinfection System 4 5 Operating and Maintenance Instructions 6 7 Fluence Dose Curves 8 Manufacture s Warranty 9 Specifications 10 11 Symbols Caution Protect...

Страница 4: ...or sc2 5 sc2 5 2 qs 330d for sc4 sc4 2 aluminum gland nut rn 001 304 stainless steel reactors with 600 grit polish A249 pressure rated tube 1 2 MNPT 3 8 FNPT combination ports for application flexibil...

Страница 5: ...to disconnect 7 Do not use this disinfection system for other than intended use potable water applications The use of attachments not recommended or sold by the manufacturer distributor may cause an...

Страница 6: ...ess is less than 7 gpg the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically If total hardness exceeds 7 gpg the water should be softened If your water chemistry co...

Страница 7: ...s the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor use only do not install disinfection system where it may be exposed to...

Страница 8: ...TTACHED TO THE DISINFECTION SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 4 Prior to connecting the power source check all connections to ensure that they are indeed secure slowly turn on water supply...

Страница 9: ...t to angle the lamp as it is removed from the chamber If the lamp is removed on an angle pressure will be applied on the inside of the quartz sleeve causing the sleeve to fracture 3 To install a new l...

Страница 10: ...he outside of the quartz sleeve with a cloth soaked in CLR or Limeaway Repeat the process as often as necessary to keep the quartz sleeve clean Be sure to remove all traces of cleaning fluid from the...

Страница 11: ...8 Fluence Dose Curves SC1 SC1 2 SC2 5 SC2 5 2 SC4 SC4 2...

Страница 12: ...1 mg L f UV Transmittance 75 call factory for recommendations on applications where UVT 75 Where total hardness is less than 7 gpg the UV unit should operate efficiently provided the quartz sleeve is...

Страница 13: ...1 8 kg 4 lbs 2 0 kg 4 5 lbs 2 9 kg 6 5 lbs Electrical Voltage 100 130V 50 60Hz 100 130V 50 60Hz 100 130V 50 60Hz Power Consumption 12 w 16 W 19 w Lamp Watts 10 W 14 w 17 w Maximum Operating Pressure...

Страница 14: ...ght 1 8 kg 4 lbs 2 0 kg 4 5 lbs 2 9 kg 6 5 lbs Electrical Voltage 200 250V 50 60Hz 200 250V 50 60Hz 200 250V 50 60Hz Power Consumption 12 w 16 W 19 w Lamp Watts 10 W 14 w 17 w Maximum Operating Pressu...

Отзывы: