![QuVIS Encore Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/quvis/encore/encore_user-manual_3787786116.webp)
SETUP – Serial menu page
This menu page is used to modify the communication settings for the two RS-232 serial ports. These
settings affect the communication ability of serial “terminal” programs and the LDV8000 control protocol
(Port B only). The serial settings of the QuVIS Encore and the connected PC must match in order for
communication between the two to function properly.
IMPORTANT!
While it is not specifically listed, the Data Bits, Parity and Stop Bits settings for both RS-
232 serial ports on the QuVIS Encore are fixed at 8N1, which is the most common setting for this type of
serial port.
Serial Menu Page Items
Description
RS-232 A Baud
Use this control to set the baud rate (rate of serial communication) for the RS-
232 A port.
RS-232 A Flow
This control changes how the flow of data is controlled between two serial
devices on this serial port. Flow control is also referred to as “handshaking”.
Note:
The system supports both software (Xon/Xoff) and hardware handshaking
(Hardware). Handshaking may also be set to
None
(Off).
RS-232 B Baud
Use this control to set the baud rate (rate of serial communication) for the RS-
232 A port.
RS-232 B Flow
This control changes how the flow of data is controlled between two serial
devices on this serial port. Flow control is also referred to as “handshaking”.
Location of Encore RS-232 Serial Ports
The system has two RS-232 serial ports on the unit. The physical connectors are male D-sub 9-pin or
DB-9.
RS-232 Port A (Primary) – This connector is located in the front of the QuVIS Encore on the
bottom edge of the front bezel underneath the adjustable front control panel.
RS-232 Port B (Secondary) – This connector is located on the back panel of the QuVIS Encore.
QuVIS Encore
Page 115
QSR Version 3.1