*SAV
(SAVe) command saves the current setup to non-volatile memory. There are 5 re-writeable
memory locations, specified by choosing an index between 1 and 5. Any of the 5 states can be restored
on startup when specified with the SYSTem:BOOTstate command. The parameters saved are the
RF
Power State, Reference Frequency, External LO1 Enabled, External LO1 Switch Override, External LO2
Enabled, External LO2 Switch Override, External Reference Enabled, External Referece Switch Override,
Tune Frequency, Upconverter Bypass Enabled, Upconverter LNA Power State, Upconverter Attenuation
1, Upconverter Attenuation 2, Upconverter ASR State, Downconverter Bypass Enabled, Downconverter
LNA Power State, and Downconverter Attenuation
. For a detailed description of the parameters saved,
see the relevent command descriptions in this manual. NOTE: The MEM_CLR button on the back panel
will rewrite the contents of states 1-5 with the contents of state 0 when depressed, serving as a reset to
factory defaults.
Syntax
*
SAV
Space
NRf
Allowed Values
The
NRf
parameter can be any integer in the range of 1 to 5.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is less than 1 or greater than 5, error
-222, "Data out of range"
occurs.
Quonset Microwave
Revision 1.2.1
84
Содержание QM1004-0.5-18
Страница 7: ...QM1004 0 5 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 2 1 vi...
Страница 15: ...QM1004 0 5 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 2 1 4...
Страница 40: ...QM1004 0 5 18 Combined RF Upconverter Downconverter User Manual 6 14 WAI 89 Quonset Microwave Revision 1 2 1 29...
Страница 105: ...Quonset Microwave www quonsetmicrowave com 1004 011 21 1004 011 21 Revision 1 2 1 November 2022...