RF Downconverter
IEEE 488.2 Command Reference
6.7 *RCL
<
NRf
>
The
*RCL
(ReCaLl) command restores a previously saved state from non-volatile memory. In addition to
factory default state 0, there are 5 re-writeable memory locations, specified by choosing an index between
1 and 5. The restored parameters are the
RF Power State, External Reference Enabled, External Ref-
erece Switch Override, Tune Frequency, External LO1 Enabled, External LO1 Switch Override, External
LO2 Enabled, External LO2 Switch Override, Downconverter Bypass, Downconverter Attenuation
. For
a detailed description of the parameters saved, see the relevent command descriptions in this manual.
When the *RCL command is called, these parameters will be applied to the device.
Syntax
*
RCL
Space
NRf
Allowed Values
The
NRf
parameter can be any integer in the range of 0 to 5.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is less than 0 or greater than 5, error
-222, "Data out of range"
occurs.