background image

Package Contents

Quoizel, Inc.
6 Corporate Parkway
Goose Creek, SC 29445

Customer Service
Phone 631.273.2700
Fax

631.231.7102

www.quoizel.com

Tools Required:

Flathead screwdriver, Phillips screwdriver, pliers, wire cutters, wire strippers, electrical tape,

safety glasses.

Bulb Recommended:
Estimated Assembly Time:
Preparation:

(2) Medium Base 60W bulbs Maximum, Alternate bulb (2) 13W CFL Maximum.

20-30 minutes

Identify and inspect all parts before beginning installation. Check package content list and diagrams

below to be sure all parts are present. If any parts are missing or damaged, do not attempt to assemble, install, or
operate the fixture. Contact customer service for replacement parts.

Warnings and Cautions

1of2

Assembly Instruction Sheet #IS-HC1612IB

For Style HC1612IB

Thank you for purchasing a Quoizel product.

Need assistance with parts or assembly? Call Quoizel customer service at 1-631-273-2700

or visit us on-line at www.quoizel.com

2014 QuoizelInc.

March2014

Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.

These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly
recommend that a licensed, professional electrician perform the installation.

Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal. Do not subject
glass parts to any shock while in operation or shattering may result.

B

Cage
x 1

Flat Washer
x 1

C

Glass
Panel
x 4

F

Hex Coupling
x 1

Stem with
Hex Nut
x 1

G

Hardware Contents

AA

Crossbar
x 1

A

Ceiling
Canopy
x 1

H

Knurled
Nut
x 1

BB

CC

DD

Lock Washer
x 1

Hex Nut
x 2

Nipple
x 1

AA

BB

CC

DD

CC

A

Step A

Step D

STEP 1

Install Crossbar

-

A.

AA)

Attach the Crossbar (

to the Outlet Box with the head of the Green

Ground Screw facing you. Secure it with Outlet Box Screws (not
included) Tighten until snug

.

.

Figure 1

Outlet Box

Outlet Box Screw
(not included)

Green Ground Screw

AA

Figure 2

Lock Washer
x 1

I

Finial
x 1

STEP 2

Install Nipple to Crossbar

-

*

Pliers is required for this step.

A. Thread one Hex Nut (CC) to the middle of the Nipple (DD). Place the

Lock Washer (BB) over the Nipple (DD) and then thread the Nipple
(DD) into the Crossbar (AA) until the Nipple (DD) is about 0.375

above the Crossbar (AA).

B. Position the center hole of the Ceiling Canopy (A) over the end of the

Nipple (DD). Adjust the Nipple (DD) so approx 0.375

of the Nipple

(DD) is protruding from the mounting hole on the Ceiling Canopy (A).
This adjustment may take a few tries.

C. Remove the Ceiling Canopy (A) and then tighten the Hex Nut (CC)

against the Crossbar (AA) to secure in place.

D. Thread another Hex Nut (CC) onto the end of the Nipple (DD).

Thread this Hex Nut (CC) on just enough so the inside surface of the
Ceiling Canopy (A) rests against it. * You may have to trial fit the
Ceiling Canopy (A) one more times to insure this distance also. This
Hex Nut (CC) is needed here to prevent you from crushing down the
center of the Ceiling Canopy (A).

E. Refer to Step 3 for wire connections.
F. Attach the Ceiling Canopy (A), the Flat Washer (F) and one Lock

Washer (BB) over the end of the Nipple (DD) as shown. Secure by
threading the Hex Coupling (H) onto the Nipple (DD) and tighten until
snug.

BB

STEP 3 - Wire Connections

A. Use standard wire connectors (not included) to make all wire

connections. (Connectors are not included with fixture.) Strip and
prepare wire ends according to instructions supplied with
connectors.

B. Connect White Supply Wire from the Outlet Box to Ribbed side Wire

from fixture.

D

Lock Screw
x 8

E

Tab
x 8

J

K

F

H

Отзывы: