Problem solving
Condition
Fault
Remedy
A lot of oil entered the
condensate treatment
device.
Compressor
malfunctioning
Replace all filters. Clean the vessels. Check the
compressor.
The service indicator
(5 - View of the unit)
rises
Too much
condensate flows into
the condensate
treatment device.
Check the compressor FAD (see section
).
Cloudy condensate at
the outlet.
Improper sizing.
It is possible that the compressor produces stable and
strong emulsions due to various environmental and working
conditions. Check if the sizing was done properly. FAD of
the installation should be equal to or lower than the
recommended value and correct filter media must be
selected based on the oil type. See section
.
Instruction book
22
2920 7197 51