background image

POWER

LIGHT

POWER

LIGHT

POWER

RECIRC.

FAN

HEATER
SWITCH

POWER

LIGHT

Heat cycle

LIGHT

+/- 0.2

o

 C

NA

+/- 0.3

o

 C

+/- 0.5

o

 C

+/- 0.5

o

 C

+/- 0.5

o

 C

+/- 0.5

o

 C

+/- 0.5

o

 C

POWER

LIGHT

POWER

LIGHT

POWER

LIGHT

POWER

OFF

HEATER
SWITCH

Heat cycle

LIGHT

Process

Set

Quincy Lab, Inc. 

*

*

*

Verify oC or oF units

(PRESS)

Increase Setpoint
Decrease Setpoint
(3 sec.) Enter/Exit

Menu Levels

 PROGRAMMABLE CONTROL

 

Standard Contents

  

(1)  Bench ER Series Oven 

(2)  Adjustable chrome wire shelf

(4)  Shelf brackets

Approvals:  

Underwriter’s UL / CUL, United States/

Canadian for laboratory equipment.

Compliance: 

UL Standard 61010-1

IEC 61010-1.

NOT FOR USE WITH FLAMMABLE 

LIQUIDS OR GASES

*

 Standard models voltage only, optional 230 voltage available. Check label on back of unit.

INTERIOR DIMENSIONS

INCHES W x H x D

(CM) W x H x D

EXTERIOR DIMENSIONS

INCHES W x H x D

(CM) W x H x D

25.5x19.7x24 25.5x19.7x24

25.5x19.7x22.5

25.5x29.7x24

33x24x35.5

33x24x35.5

33x34x35.5

33x24x35.5

WEIGHT

SHIPPING

STAND ALONE

185

165

185

165

225

200

195

170

STANDARD ELECTRICAL

PLUG/NEMA

120/8.75*

1050

5-15P*

120/16*

1920

5-20P*

120/16*

1920

5-20P*

230/12.5

2850

6-20P

64x49.5x60

64x49.5x60

64x49.5x57

64x75.5x60

83x60x90

83x60x90

83x86x90

83x60x90

TEMPERATURE RANGE

A 25F to

300 F/150 C

450 F/232 C

450 F/232 C

550 F/287 C

CONTROL STABILITY

@ 100C

@ 200C

Issue  Rev A  0320

Copyright Quincy Lab Inc. 2020

MODEL

21-250ER

SPECIFICATIONS

VOLTS/AMPS

WATTS

Common Unit Construc�on

MODEL

21-350ER

MODEL

31-350ER

MODEL

51-550ER

Exterior:

Insula�on:

Thermo-control:

Powder Coated Steel

Fiberglass

Hydraulic

Interior:

Motor:

Heater:

Aluminized Steel (SS op�onal)

Sealed Ball Bearing

Resis�ve - Tubular Incoloy

Bench Series Ovens Operating Manual

ER Models 21 /31 /51

+/- 0.5

o

 C

+/- 0.5

o

 C

25.5x29.7x24

33x34x35.5

225

200

120/16*

1920

5-15P*

64x75.5x60

83x86x90

300°F/150°C

MODEL

31-250ER

uincy

ab

Quincy Lab Inc.  1925 N. Leamington Ave.  Chicago,  Illinois     1800-482-4328

PAGE 1

PAGE 8

Содержание Bench 21-250ER

Страница 1: ...5x19 7x24 25 5x19 7x22 5 25 5x29 7x24 33x24x35 5 33x24x35 5 33x34x35 5 33x24x35 5 WEIGHT SHIPPING STAND ALONE 185 165 185 165 225 200 195 170 STANDARD ELECTRICAL PLUG NEMA 120 8 75 1050 5 15P 120 16 1...

Страница 2: ...trains use assistance when moving or liftiing WALL 6 10 6 minimum from wall to rear blower housing CLEARANCE REQUIREMENTS 20AMP 5 20P 15AMP 5 15P 120 Volt Units 20AMP 6 20P 15AMP 6 15P 230 Volt Units...

Страница 3: ...ts located on each inner side of the oven Orientate the bracket in the down or L position This position guides the shelf in and out and protects the side wall from being scratched The bracket may also...

Страница 4: ...ing HEATER SWITCH HEAT FAN COOL The heater switch in the off down or fan cool position allows for convenient ambient air drying of articles or to more slowly evenly cool heated articles without having...

Страница 5: ...ce of the oven exhaust chamber or piping and present a fire hazard over time Contact an HVAC engineer for assistance with installation or questions regarding proper venting requirements in your specif...

Страница 6: ...oll back and forth through level functions Level P is the Ramp Soak program level See separate Ramp Soak Programming Operating Manual PRESS Sensorburn out uP SC dn sc 1u 2d 1d 2u Reverseoutputs 1r 2d...

Страница 7: ...you desire better performance For example If you want better run up performance once a load is placed start the auto tune function just after you ve place the load If you want the best stability afte...

Страница 8: ...quincylab com Technical Support For a complete list of replacement componets part and additional equiptment visit us on the web at www quincylab com or contact your dealer for availability and pricin...

Отзывы: