Section VII - Compressor Fluids
Quincy Compressor
®
- QSB/T
™
45
Cleaning and Flushing With QuinSyn Flush
Normal Machines
Flushing
clean
machines presently using:
A. Mineral Oils -
Drain compressor thoroughly while hot including
all the low areas. Shut down and lockout the
machine. Detach lines and drain. Inspect machine;
if clean, change filters and separator elements and
proceed as follows:
Fill with QuinSyn Flush and run machine until it
reaches normal operating temperature. Drain and
refill with a fresh charge of the QuinSyn fluid
selected for your machine. Send a fluid sample to
Quincy Compressor
®
Fluid Analysis at 200 hours.
B. Polyalklene glycols (PAG) or Silicone -
Drain compressor thoroughly as in (A). Fill
machine with QuinSyn Flush and run for 500 hours.
Send a fluid sample to Quincy Compressor
®
Fluid
Analysis. Flush may need to be repeated several
times. Analysis will determine if further flushes are
needed.
Fill with the QuinSyn fluid selected for your
machine. Send a fluid sample to Quincy
Compressor
®
Fluid Analysis at 200 hours.
Varnished Machines
Always clean
slightly varnished
machines using mineral
oils or PAO fluids with QuinSyn Flush using the
following procedure:
Drain thoroughly as in (A) and fill with QuinSyn Flush.
Run the machine for 300 hours and take a fluid sample.
Send fluid sample to Quincy Compressor
®
Fluid Analysis
to determine if further flushes are needed. Continue
compressor operation until results of fluid analysis are
reported. Drain or continue operation as advised by fluid
analysis.
Always clean
medium to heavily varnished
machines
using mineral oils or PAO fluids with QuinSyn Flush
using the following procedure:
Drain thoroughly as in (A) and fill with QuinSyn Flush.
Run the machine for 300 hours and take a fluid sample.
Send fluid sample to Quincy Compressor
®
Fluid Analysis
to determine if further flushes are needed. Run the flush
for an additional 300 hours. Drain thoroughly as in (A)
and inspect the compressor. If clean, flush with another
half charge of QuinSyn Flush and run for 30 minutes.
Drain completely. Change filters and separator elements
and fill with a fresh charge of the QuinSyn fluid selected
for your machine. Send fluid sample to Quincy
Compressor
®
Fluid Analysis at 200 hours.
Extremely varnished
machines should not be put back
into service until mechanically or chemically cleaned.
After proper cleaning, fill with a fresh charge of the
QuinSyn fluid selected for your machine. Send fluid
sample to Quincy Compressor
®
Fluid Analysis at 200
hours.
Содержание QSB Series
Страница 2: ......
Страница 9: ...Section I General Quincy Compressor QSB T 5 MODEL IDENTIFICATION...
Страница 21: ...Quincy Compressor QSB T 17 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 27: ...Quincy Compressor QSB T 23 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 71: ...Quincy Compressor QSB T 67 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 72: ...Appendix A Dimensional Drawings 68 Quincy Compressor QSB T QSB 15 50 HP air cooled...
Страница 73: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 69 QSB 15 50 HP water cooled...
Страница 74: ...Appendix A Dimensional Drawings 70 Quincy Compressor QSB T QST 15 50 HP air cooled 120 gallon tank...
Страница 75: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 71 QST 15 50 HP water cooled 120 gallon tank...
Страница 76: ...Appendix A Dimensional Drawings 72 Quincy Compressor QSB T QST 15 50 HP air cooled 200 gallon tank...
Страница 77: ...Appendix A Dimensional Drawings Quincy Compressor QSB T 73 QST 15 50 HP water cooled 200 gallon tank...