3.2.  Specialty Fan Wiring - Timer (see Figure 3.2A)

For wiring of a Specialty Series Fan with a timer. This wiring method works with all of our Specialty Series fans. 
We recommend using this method if installing a Roof Mount fan as a whole house fan. This also works well 
with a Garage fan.

1. 

For this installation, you will need a 2 & 3 wire Romex, and an 8 Hour Timer. 

2. 

Begin wiring the timer. From your 3 wire Romex, using a wire nut, tie the two red wires together, the 
two white wires together, the two black wires together, and the two ground wires together (copper 
and green).

3. 

Open up the junction box that is connected to the fan. Bring your 2 wire and 3 wire into the junction 
box. 

3. 

Tie the white common wires from the fan, the power source, and the timer together. Then, using the 
green ground screw, ground a copper jumper wire and the green wire from the fan to the handy box. 

4. 

With a wire nut, tie the black wire from the fan to the red wire from the timer. 

5. 

Then, tie the black wire from the power source to the black wire from the timer.

6. 

Lastly, tie the copper ground wire from the power source and the copper jumper wire from the fan to 
the copper ground wire coming from the 14-3 wire from the timer.

Figure 3.2A

Ground the fan to the junction box 

using the green ground screw

Specialty Series Fan

Junction

Box

Power

Source

14-2 Wire

14-2 Wire

8 HOUR

4 HOUR

2 HOUR

1 HOUR

HOLD

Bare Copper Wires Tied 

Together

Match Wire

Colors Together

14-3 W

ire

Ground the fan to the junction box 

using the green ground screw

Specialty Series Fan

Junction

Box

Power

Source

14-2 Wire

14-2 Wire

8 HOUR

4 HOUR

2 HOUR

1 HOUR

HOLD

Bare Copper Wires Tied 

Together

Match Wire

Colors Together

14-3 W

ire

Содержание AFG

Страница 1: ...SEE HEAR FEEL THE QUIETCOOL DIFFERENCE THE NATURAL CHOICE FOR ENERGY SAVINGS INSTALLATION GUIDE SPECIALTY SERIES FANS...

Страница 2: ...personnel should service the QuietCool system The user should not attempt to service the product 7 Building Codes Always follow Local Building Codes when installing appliances CONTENTS 1 SYSTEM OVERVI...

Страница 3: ...rgy efficient attic fan and the AFG CON 3 0 the most powerful residential attic fan Both fans have stellar energy efficiency and astounding airflow QuietCool Garage Fans The QuietCool Garage Fans offe...

Страница 4: ...FT 1560 CFM GA ES 1500 2 SQ FT 2 SQ FT 1452 CFM GX ES 1100 1 5 SQ FT N A Exhausts Directly to Outside 1103 CFM RM ES 1100 1 5 SQ FT N A Exhausts Directly to Outside 1130 CFM RM ES 2200 3 SQ FT N A Ex...

Страница 5: ...the gable fan to your gable vents as shown in the following steps 1 Flush Mount The AFG can be mounted flush to a rectangular type louver by fastening through the mounting brackets to the frame of the...

Страница 6: ...ge Attic Fan Now it s time to find the exact location using a stud finder Locate the ceiling studs and mark the location for the fan to be installed see Figure 2 2A One side of the cut out should be d...

Страница 7: ...a drywall saw cut out the opening Remove the drywall cutout and clear away insulation if applicable similar to Figure 2 2C 4 From the interior drill a hole through the exterior at the four corners of...

Страница 8: ...rance Now using a drywall saw cut out the drywall using the rough opening measurements shown in Figure 2 4A 2b When installing your RM fan as a whole house fan without a duct find the exact ceiling lo...

Страница 9: ...he following diagram as it will dramatically affect the sound level of the fan NEVER install the ceiling grille directly underneath the fan We recommend a grille offset of 3 to 4 feet Figure 2 4A Figu...

Страница 10: ...a wire nut tie the white common wires together Using the green ground screw ground the green wire from the fan to the handy box NOTE If you are NOT installing the thermostat in the junction box on the...

Страница 11: ...14 2 Wire OFF 5 5 65 75 8 5 50 60 70 80 90 14 2 Wire Figure 3 1B Thermostat Wiring in a Remote Location Ground the fan to the junction box using the green ground screw Specialty Series Fan Junction Bo...

Страница 12: ...source and the timer together Then using the green ground screw ground a copper jumper wire and the green wire from the fan to the handy box 4 With a wire nut tie the black wire from the fan to the re...

Страница 13: ...n your garage Don t let your garage get hot and worry about damage to your vehicles motorcycles boat etc just flip on your QuietCool Garage Fan 4 3 QuietCool Roof Mount Fans The QuietCool Roof Mount F...

Страница 14: ...00 is the perfect fan to cool and ventilate your garage man cave or workshop through the wall Watts Airflow CFM Watt 69 1103 CFM 15 9 RM ES 1100 The RM ES 1100 is the perfect fan to cool and ventilate...

Страница 15: ...tall or install any components 3 Product failure or damage due to faulty installation including motor issues caused by incorrect wiring abuse misuse unauthorized alteration to factory specs lack of ma...

Страница 16: ...14 1 888 QUIETCOOL QuietCool is Proudly Designed and Built in California 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM...

Отзывы: