03
User and installation guide Room Temperature Controller
1. Principle of operation
The programmable room temperature controller QuickTherm HF Room Thermostat Smart allows programming switching events (up to 9) and temperatures
according to personal needs. After installation the device automatically shows the time of day and the room temperature. In AUTO mode, the Heater
(Cooler) will be automatically activated
according to programmed time and temperature. Program 1 is the default pre-set program (see 8.). The room temperature will be controlled according to
the temperature measured by the internal or remote sensor. The Heater will be switched on when the temperature drops below the current set-point.
Actual Day
Actual Room Temperature
Calling for Heat (Blinks if detached from power module or there is no mains power)
Helping text
Mode = AUTO
Time = 14:31
2. Installation
Caution!
This device must be installed by a qualified electrician, according to the wiring diagram on the device and in compliance with all applica-
ble safety regulations.
Appropriate installation measures must be taken to achieve the requirements of protection class II.
This device, is used to control the temperature only in dry rooms, under normal environmental conditions. This electronic device conforms
to EN 60730, It is an “independently mounted control” and works according to operating principle 1C.