5.3 Button Descriptions

Button

Function Descriptions

CH1~CH3

1.Click coordinate button to select Channel numbers.
2.Press and hold the Channel button to store the airflow and

temperature of the current Channel.

▲/▼

1.Temperature regulation
2.Press and hold ▲&▼ buttons simultaneously to enter the

temperature calibration menu.

5.4 Main Menu

Icon

Descriptions

Air volume

CH0

Temporary channel

COOL

Cooling status

Содержание 959D+

Страница 1: ...QUICK 959D SMD REWORK STATION Instruction Manual Thank you for purchasing our products Please keep the instruction manual properly for future reference...

Страница 2: ...utton Descriptions 5 5 4 Main Menu 5 6 Installation and Connection 6 6 1 Installation 6 6 2 Connection 6 7 Operation 7 8 Password Setup 7 9 Parameter Setup 8 10 New Password Setup 9 11 Temperature Cal...

Страница 3: ...he product WARNING Products should be used away from magnetic field Do not place the product where the surface is vibrated or subject to shocks Do not install the product where it maybe wet Do not use...

Страница 4: ...small or large air volume heater 3 Product Features Closed loop sensor microcomputer control temperature with high power and rapid temperature heat Air volume adjustable digital display and easy to ad...

Страница 5: ...Display LCD Power 500W Max 580W Max Input voltage 110V AC 220V AC Temperature range 100 500 Air volume 1 100 Level Adjustable Airflow 40L min Max Dimensions L W H 110 180 151mm Weight About 1 6 Kg 5...

Страница 6: ...4 5 2 Part Descriptions...

Страница 7: ...annel numbers 2 Press and hold the Channel button to store the airflow and temperature of the current Channel 1 Temperature regulation 2 Press and hold buttons simultaneously to enter the temperature...

Страница 8: ...ace the mounting hole of the handle holder on the two screw holes on the product and install two screws and tighten them 3 Install the handle holder and put the handle on the holder then check whether...

Страница 9: ...to select Channel 1 Channel 2 Channel 3 respectively Long press the Channel button to store the parameters of the current Channel Sleeping Place the handle on the holder to cool The station will enter...

Страница 10: ...is wrong then directly enter the second password and the input method is same as the first time There are two chances of password input If the first password input is wrong you can directly enter the...

Страница 11: ...sword setting is not successful Return to the parameter setting and the password remains unchanged If the same number is entered twice the window will show OK which means the password is set successfu...

Страница 12: ...ndle 4 Remove the orange and yellow cables connected in the Heater 5 Remove a screw of Steel pipe plug the grounding cable and remove the Steel pipe Check whether the quartz tube is damaged or not 6 R...

Страница 13: ...After replacing the heater test the following parameters 8 Calibrate the temperature refer to Soldering temperature calibration 13 Troubleshooting No Error Message Fault Descriptions 1 H E Indicates t...

Страница 14: ...12 14 Nozzles...

Страница 15: ...le List Nozzle A1124 A1130 A1300 Heater A1147 220V Steel pipe 857 Mica paper 857 74x18mm ceramic packing Handle 857 Holder 957D The handle sheath Fuse 3A 5x20mm 40003228 Pump components Fan module 959...

Страница 16: ......