10
Note: If there is no QUICK196, it is recommended that the temperature measuring head
of the external sensor of the thermometer be placed 3
~
5mm away from the nozzle for
temperature test.
12. Replacement of the Heater
12.1 Steps of removing the Heater
1) Remove the spring.
2) Unscrew the three
①
Screws .
3) Pull out
②
Steel pipe &
⑤
Holder from
⑥
Handle.
4) Remove the orange and yellow cables connected in the
③
Heater.
5) Remove a screw of
②
Steel pipe, plug the grounding cable and remove the
②
Steel
pipe.Check whether the quartz tube is damaged or not.
6) Remove the
③
Heater from
④
Plug.
7) Remove the heater.
NOTE: :The steps need to be operated in the OFF status, and the handle should be
cooled in the room temperature.
12.2 Steps of replacing the Heater
1) Insert the
③
Heater, and connect it into green plug.
2) Connect the yellow cable into the heater of the yellow cable , and the orange into the
red.