9
10. New Password Setup
1) After entering the new password setting, the window displays “---” and the hundreds’
digit blinks.
2) Then adjust the middle knob to change the hundreds’ digit, press the “▲” button to
move the digit, and then the tens’ digit starts flashing to be set. When the digit is set, press
and hold the “
▲
” and “
▼
” button at the same time to confirm. The second setting
method of password is the same as the first setting method of password.
Note:
If the numbers of the password entered twice before and after are not the same, the
window shows “ERR”, indicating that the password setting is not successful. Return to
the parameter setting, and the password remains unchanged.
If the same number is entered twice, the window will show “OK”, which means the
password is set successfully and return to the parameter setting. Turn off and restart the
product, and the password will take effect.
11. Temperature Calibration
1) Set the product temperature to 300
℃
. Use QUICK196 to test the temperature of the air
outlet and write down the readings.
2) Press and hold the “▲”and “▼” button about 2s, the display will show “CAL” and
enter the temperature calibration mode.
3) Press “▲” or “▼” to adjust the temperature to the measured value.
4) Press and hold the “▲” and “▼” button about 2s, and return to the main interface with
a beep. That is, the temperature calibration is successful.