L10 Hardware Design
Table 20: The ESD endurance table (Temperature: 25
, Humidity: 45 %)
℃
Pin
Contact discharge
Air discharge
Antenna port
±5KV
±10KV
VCC,GND ±4KV
±8KV
Others ±4KV
±8KV
5.6 Reliability test
Table 21: Reliability test
Test term
Condition
Standard
Thermal shock
-30°C...+80°C, 144 cycles
GB/T 2423.22-2002 Test
Na
IEC 68-2-14 Na
Damp heat, cyclic
+55°C; >90% Rh 6 cycles for 144 hours
IEC 68-2-30 Db Test
Vibration shock
5~20Hz,0.96m
2
/s
3
;20~500Hz,0.96m
2
/s
3
-3dB/oct,
1hour/axis; no function
2423.13-1997 Test Fdb
IEC 68-2-36 Fdb Test
Heat test
85° C, 2 hours, Operational
GB/T 2423.1-2001 Ab
IEC 68-2-1 Test
Cold test
-40° C, 2 hours, Operational
GB/T 2423.1-2001 Ab
IEC 68-2-1 Test
Heat soak
90° C, 72 hours, Non-Operational
GB/T 2423.2-2001 Bb
IEC 68-2-2 Test B
Cold soak
-45° C, 72 hours, Non-Operational
GB/T 2423.1-2001 A
IEC 68-2-1 Test
L10_HD_V1.01