![Quectel EC25 series Скачать руководство пользователя страница 51](http://html2.mh-extra.com/html/quectel/ec25-series/ec25-series_command-manual_3618187051.webp)
LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 50 / 231
Parameter
4.3.13. AT+QCFG="urc/ri/ring" RI Behavior When RING URC is Presented
AT+QCFG="urc/ri/ring"
,
AT+QCFG="urc/ri/smsincoming"
and
AT+QCFG="urc/ri/other"
control the
RI (ring indicator) behavior when a URC is reported. These configurations will be stored into NV
automatically. The ring indicator is active low.
AT+QCFG="urc/ri/ring"
specifies the RI behavior when
URC
RING
is presented to indicate an incoming call.
The sum of parameter
<activeduration>
and
<inactiveduration>
determines
the interval time of “RING”
indications when a call is coming.
Parameter
<enable>
0
Refused to establish multi PDNs with the same APN profile
1 Allowed to establish multi PDNs with the same APN profile
AT+QCFG="urc/ri/ring"
RI Behavior When RING URC is Presented
Write Command
AT+QCFG="urc/ri/ring"[,<typeri>[,<pul
seduration>[,<activeduration>[,<inacti
veduration>[,<ringnodisturbing>]]]]]
Response
If
<typeri>
,
<pulseduration>
,
<activeduration>
,
<inactiveduration>
and
<ringnodisturbing>
are omitted,
return the current configuration:
+QCFG:
"urc/ri/ring",<typeri>,<pulseduration>,<activeduration>,
<inactiveduration>,<ringnodisturbing>,<pulsecount>
OK
If all configuration parameters are entered, set the RI
behavior when
RING
URC is presented:
OK
ERROR
If there is any error related to ME functionality:
+CME ERROR: <err>
Maximum Response Time
300ms
<typeri>
RI behavior when URCs are presented
"off"
No change. Ring indicator keeps inactive.
"pulse"
Pulse. Pulse width determined by
<pulseduration>
.
"always"
Change to active. RI behavior can be restored to inactive by
AT+QRIR
.