LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 202 / 231
These parameters will not be saved.
Example
AT+QLDTMF=?
//Query the range.
+QLDTMF: (1-1000),(0-9,*,#,A-D)
OK
AT+QLDTMF=2,“A,B,1,2,#”
//Play A,B,1,2,#, on time & mute time is 200ms.
OK
AT+QLDTMF
//Stop playing.
OK
12.15. AT+QLTONE Play a Local Customized Tone
The command is used to play a local customized tone, use
<period_on>
to indicate play time and
<period_off>
to indicate mute time, and
<duration>
to indicate total time.
Parameter
AT+QLTONE Play a Local Customized Tone
Test Command
AT+QLTONE=?
Response
+QLTONE: (0,1),(100-4000),(0-1000),(0-1000),(0-15300000)
OK
Write Command
AT+QLTONE=<mode>[,<frequency>,
<period_on>,<period_off>,<duration>
]
Response
OK
+CME ERROR: <err>
After the tone is completely played:
+QLTONE: 0
Maximum Response Time
300ms
<mode>
0
Stop playing
1
Start to play
<frequency>
Tone‟s frequency. The range is 100-4000, the unit is Hz.
NOTE