GV600WG User Manua
l
QSZTRACGV600WGUM0102 10
3.8.
Digital Outputs
There are four digital outputs on GV600WG. All are of open drain type and the maximum drain
current is 150 mA. Each output has a built-in over current PTC resettable fuse.
Figure 9.
Digital Output Internal Drive Circuit
Table 9.
Electrical Characteristics of Digital Outputs
Logical Status
Electrical Characteristics
Enable
<1.5V @150 mA
Disable
Open drain
Figure 10.
Typical Connection with a Relay