background image

GV50VC User Manual 

 

 

TRACGV50VCUM0011 

Document Title 

GV50VC User Manual 

Version 

1.01 

Date 

2016-03-18 

Status 

Release 

Document Control ID 

TRACGV50VCUM001 

 

 

 

General Notes 

Queclink  offers  this  information  as  a  service  to  its  customers,  to  support  application  and 
engineering efforts that use the products designed by Queclink. The information provided is 
based upon requirements specifically provided to Queclink by the customers. Queclink has 
not  undertaken  any  independent  search  for  additional  relevant  information,  including  any 
information  that  may  be  in  the  customer’s  possession.  Furthermore,  system  validation  of 
this  product  designed  by  Queclink  within  a  larger  electronic  system  remains  the 
responsibility  of  the  customer  or  the  customer’s  system  integrator.  All  specifications 
supplied herein are subject to change. 

 

Copyright 

This document contains proprietary technical information which is the property of Queclink. 
The  copying  of  this  document,  distribution  to  others,  and  communication  of  the  contents 
thereof,  are  forbidden  without  express  authority.  Offenders  are  liable  to  the  payment  of 
damages.  All  rights  are  reserved  in  the  event  of  a  patent  grant  or  registration  of  a  utility 
model or design. All specifications  supplied herein are  subject  to change  without  notice  at 
any time. 

 

Copyright ©  Queclink Wireless Solutions Co., Ltd. 2016 
 

WARNING: The device complies with part 15 of the FCC Rules. Operation is subject to the 
following two conditions: 
(1)

 

The device may not cause harmful interference, and 

(2)

 

The device must accept any interference received, including interference that may cause 
undesired operation. 

Change or modification not expressly approved by the party responsible for compliance 
could avoid the user’s authority to operate the equipment. 
FCC RF Exposure Statement: 
For the product, under normal use condition is at least 20cm away from the body of the user, 
the user must keeping at least 20cm distance to the product. 

Содержание GV50VC

Страница 1: ...GV50VC User Manual TRACGV50VCUM0010 GV50VC User Manual CDMA2000 1X GPS Tracker TRACGV50VCUM001 Version 1 01 GV50VC...

Страница 2: ...nical information which is the property of Queclink The copying of this document distribution to others and communication of the contents thereof are forbidden without express authority Offenders are...

Страница 3: ...roduct Overview 7 2 1 Appearance 7 2 2 Interface Definition 7 2 3 LED Description 8 2 4 Power Connection 8 2 5 Ignition Detection 9 2 6 Digital Output Input connection 10 2 7 Digital Output 12 3 Getti...

Страница 4: ...PIN CONNECTIONS 8 TABLE 4 LED DESCRIPTION 8 TABLE 5 ELECTRICAL CHARACTERISTICS OF IGNITION DETECTION 9 TABLE 6 ELECTRICAL CHARACTERISTICS AS DIGITAL OUTPUTS 10 TABLE 7 ELECTRICAL CHARACTERISTICS AS DI...

Страница 5: ...URE 3 TYPICAL POWER CONNECTION 9 FIGURE 4 TYPICAL IGNITION DETECTION 10 FIGURE 5 AS DIGITAL OUTPUT INTERNAL DRIVE CIRCUIT 10 FIGURE 6 TYPICAL CONNECTION WITH BUZZER AS DIGITAL OUTPUT 11 FIGURE 7 TYPIC...

Страница 6: ...GV50VC User Manual TRACGV50VCUM0015 0 Revision history Revision Date Author Description of change 1 00 2016 03 18 Docter Xu Initial Version...

Страница 7: ...k to transfer reports of Emergency geo fence boundary crossings low backup battery or scheduled GPS position as well as many other useful functions Users can also use GV50VC to monitor the status of a...

Страница 8: ...rance Figure 1 GV50VC Appearance 2 2 Interface Definition The GV50VC has a 7 PIN interface connector It contains the connections for power I O The sequence and definition of the7PIN connector are show...

Страница 9: ...no data or data format error Slow flashing GPS chip is searching GPS info Fast flashing GPS chip has gotten GPS info ON Table 4 LED Description Note 1 CELL LED cannot be configured 2 GPS LED can be c...

Страница 10: ...ing to the ignition switch is to find a non permanent power source that is only available when the vehicle is running For example the power source for the FM radio IGN signal can be configured to star...

Страница 11: ...d the maximum drain current is150mA as a digital Output and a negative trigger as digital Input Electrical Characteristics of the digital input Figure 5 As Digital Output Internal Drive Circuit Table...

Страница 12: ...buzzer AS Digital Output Table 7 Electrical Characteristics AS Digital Inputs Logical State Electrical Characteristics Active 0V to 0 8V Inactive Open The following diagram shows the recommended conne...

Страница 13: ...GV50VC Ti is of open drain type and the maximum drain current is 150mA Figure 8 Digital Output Internal Drive Circuit Table 8 Electrical Characteristics AS Digital Outputs Logical State Electrical Ch...

Страница 14: ...GV50VC User Manual TRACGV50VCUM00113 Figure 9 Typical Connection with Relay...

Страница 15: ...t Table 9 Part List Name Picture GV50VC Locator 73mm 50mm 13 2mm 3 2 GV50VC External Cable Interface Table 10 GV50VC User Cable Colour definition Definition Colour PIN No Cable RXD Green 1 TXD Gray 2...

Страница 16: ...anual TRACGV50VCUM00115 3 3 Turn on Turn off Turn On Connect device to external battery and it will turn on automatically PWR LED will light on Turn Off Disconnect device from external battery and it...

Страница 17: ...n the Internet Unable to power off GV50VC Unable to power off GV50VC if charger is connected Disconnect charger and try again GV50VC can t get successful GPS fixing The GPS signal is weak Please move...

Отзывы: