QS-220-PL
3.3.
EXTENDED SET: QS-SB2 CONNECTION - 4 ACTUATORS
In rigs with 4 actuators, both power cabinets have to be connected to each other, con-
nect them by applying following steps:
1.
Plug in the Motion Lock Switch into the ”ML UP” port in the QS-SB2 power cabinet.
2.
Connect Motion Lock ”ML DN” port to Motion Lock ”ML UP” port using motion lock
interlink cable.
3.
Connect M-BUS ports in both power cabinets using BUS communication cable.
4.
Put M-BUS terminator in the last M-BUS port in second QS-SB2 power cabinet.
5.
Connect M10 to M-BUS port in QS-SB2 power cabinet.
6.
Connect PC to the M10 controller using USB cable.
7.
In both power cabinets, plug in the power cables with adequate plugs into power
sockets.
8.
Set the appropriate position on the CFG Switch according to the actuators layout
of your choice (more information about CFG Switch position and layout selection
in section 3.5 on page 18).
INFO
Order of connecting the cables is not important, you can connect the M10 con-
troller or Motion Lock Switch to either of the QS-SB2 power cabinet. Keep the
CFG switches according to appropriate layout. Check section 3.4 and 3.5 for lay-
out setup.
User Manual R3.0
16