![Qubic System QS-220-PL Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/qubic-system/qs-220-pl/qs-220-pl_user-manual_3557254019.webp)
QS-220-PL
3.2.
INTRO SET: QS-SB2 CONNECTION - 2 ACTUATORS
To connect QS-220-PL apply following steps:
1.
Plug Motion Lock Switch into Motion Lock ”ML UP” port in the QS-SB2 power cab-
inet.
2.
Connect M10 to M-BUS port in power cabinet using BUS communication cable at
both ends.
3.
Put M-BUS terminator (RJ45 plug with resistor) in second M-BUS port in the QS-SB2
power cabinet.
4.
Connect PC to the M10 controller using USB cable.
5.
Plug in the power cable with adequate type of plug into power socket in the QS-
SB2 power cabinet.
INFO
Order of connecting the cables is not important, keep the CFG switch according
to appropriate layout. Check section 3.4 and 3.5 for layout setup.
User Manual R3.0
15
Содержание QS-220-PL
Страница 1: ......
Страница 14: ...QS 220 PL 2 3 DIMENSIONS User Manual R3 0 10...
Страница 23: ...QS 220 PL User Manual R3 0 19...
Страница 24: ...QS 220 PL User Manual R3 0 20...
Страница 45: ...QS 220 PL 13 NOTES User Manual R3 0 41...
Страница 46: ......