4.3.2.30.2 All Parameters Erase - PERA
The Parameters Erase command erases the stored parameter set for all modes. It has no impact on the current
operating parameter set. When the receiver brick is power cycled, all operating parameters set are set to defaults.
Example:
PERA
Erasing parameter data... ok
4.3.2.30.3 Parameter Load - PLD
The Parameter Load command loads the stored parameter set into the current operating parameter set.
Example:
PLD
Loading parameter data... ok
4.3.2.30.4 Parameter Reset - PRS
The Parameter Reset command resets the current operating parameter set to the defaults. This does not affect the
stored parameter set.
Example:
PRS
Initializing parameter data... ok
4.3.2.30.5 Parameters Save - PSV
The Parameters Save command writes the current operating parameter set into a (previously erased) stored
parameter set.
Example:
PSV
Saving parameter data... ok
4.3.2.30.6 Reset to Factory Defaults - RFD
The Reset to Factory Defaults command erases the stored parameter set for ALL modes then resets the current
operating parameter set to the defaults including mode (it changes to the default mode).
Example:
RFD
WARNING: ALL CONFIGURATION PARAMETER DATA IS ABOUT TO BE ERASED!!
THIS CANNOT BE UNDONE!!
Enter "YES" to continue!$
Aborted
4.3.2.31 Power Level - PL
The PL command reports or sets the current input power level setting.
PL [<t>|C <m>|H <e>|S <s>|P <p>|M <t>|F <e>]
<t> - Sets power level information tracking display to <t>