3
rd
Generation Compact RDMS
TM
Telemetry Receiver
55
Quasonix, Inc.
4k4 – 4k Rate 4/5
1k4 – 1k Rate 4/5
A <t> - Sets ASM threshold to <t>, 0 to 65535. This is not a stored parameter.
I <s> - Sets half iteration scale to <s>, 0.100 to 1.000
Examples:
LDPC
LDPC mode 4k Rate 2/3
LDPC decode ASM threshold 192
LDPC decode half iteration scale 0.900
LDPC A 42
LDPC decode ASM threshold 42
LDPC I .567
LDPC decode half iteration scale 0.567
4.3.2.26 Modulation Index - MI
The MI command displays and controls modulation index scale settings.
MI [<s>|M <m>|TH <h>|THE <e>|AD <d>|AS <s>|P <e>]
<s> - Sets modulation index scale to <s>, 0.350 to 8.000, this forces the mode to hold at the specified value
M <m> - Sets modulation index scale mode to <m>
where: <m> - Mode
O - Off (sets scale 1.0 for nominal deviation of 0.70)
H - Hold
A - Acquire
T - Tracking
TH <h> - Sets tracking-mode hold below Eb/N0 of <h>, -20.000 to 30.000
THE <e> - Sets tracking-mode hold below Eb/N0 enable to <e>
where: <e> - Enable
0 - Disabled
1 - Enabled
AD <d> - Sets acquire mode minimum delta H to <d>, 0.000 to 8.000
AS <s> - Sets acquire mode settling time to <s>, 20 to 10000 ms with a 10 ms resolution
P <e> - Sets the modulation index scale parameter (mode and H value) persistence to <e>
where: <e> - Enable
0 - Disabled