Quasar 3140 Скачать руководство пользователя страница 1

QUASAR CODES 3140 - DTMF Telephone Relay Switcher

General Guidelines for Electronic Kits and Assembled Modules 

Thank you for choosing one of our products. Please take some time to carefully read the important 
information below concerning use of this product. The assembly and operating instructions are on the 
following pages. 
 

WEEE Directive (Waste Electrical and Electronic Equipment)  
Notice To All European Union Citizens. Important environmental information 
about this product. 

The crossed out wheeled bin symbol on this product, package or documentation 
indicates that disposal of this product after its lifecycle could harm the environment. 
Do not dispose of this product (or batteries if used) as unsorted municipal waste. It 
should be disposed by a specialized company for recycling. 
The unit should be returned to your distributor or to a local recycling service. Please 

respect the local environmental rules. If in doubt contact your local authorities about waste disposal rules. 
 

Safety: General rules concerning safe use of our Kits or Modules. 
To ensure your safety, please observe these safety measures. In no way are these complete. As 
safety requirements vary, please check with your local authorities, in order to comply with local 
requirements. If in doubt, seek the help of a qualified person. 

 

Battery or wall-adaptor operated devices are safe devices. They do not require special attention 
unless mains voltage is connected to an output e.g. a relay. 

 
To ensure electrical safety, and also protection from fire or personal injury, make sure your 
mains operated equipment complies with these safety hints: 
 

 

Use a suitable plastic enclosure. If a metal enclosure is used, make sure it is properly earthed. 

 

Use a power switch if the device consumes more than 10W. Use a double pole switch for mains 
operated, transformer-less kits. 

 

Mount a fuse in series with the mains switch. Use a slow blow (T) 50mA fuse for transformers up 
to 10W and a 100mA fuse for transformers up to 20W. 

 

Use a mains input connector, or a robust power cord with a clamp. 

 

Internal wiring carrying mains voltages must have a minimum cross-sectional area of 0.5mm

2

 
If supplied, attach the power rating label near the power cord of the device and fill-out the mains voltage, 
frequency, power consumption and fuse values. 
 

Troubleshooting and Support 

90% of non working kits are due to poor soldering.  
We operate a Get-You-Going service for non-working kits but there is a charge based on the time and 
components needed to complete the repair. Quite often it is not economically viable for us to repair and it 
is cheaper to supply a new ready made product at full cost. 
 

Disclaimer 

Quasar Electronics reserves the right to change product specifications or to discontinue products without 
notice. Quasar Electronics cannot be held responsible for any loss or damage, direct or indirect, which 
might occur from the use of a product. Quasar Electronics Kits or Modules are intended for educational 
and demonstration purposes only. They are not intended for use in commercial applications. If they are 
used in such applications the purchaser assumes all responsibility for ensuring compliance with all local 
laws. In addition, they are not suitable for use as or as a part of life support systems, or systems that might 
create a hazardous situation of any kind.  

Содержание 3140

Страница 1: ...perated equipment complies with these safety hints Use a suitable plastic enclosure If a metal enclosure is used make sure it is properly earthed Use a power switch if the device consumes more than 10...

Страница 2: ...d DTMF digit is detected the 4 bit code is placed on pins 11 14 and a data avaliable output pin 15 is set to a logic high The output relays RL1 4 are controlled via the relay driver IC6 One output fro...

Страница 3: ...w quasarelectronics com jpg 3140_2 jpg PRE TESTING Insert IC7 MAX666 and connect a 12 15Vdc power supply to the DC input jack Use a multimeter to check the 5V supply Easiest place to measure this is a...

Страница 4: ...this feature is disabled the unit expects the the call to be answered externally eg by an answering machine Everything else works as normal including entering a valid password The only difference is...

Страница 5: ...lder BT wiremen is often approaching art in its perfection The BT Drop Cable The cable coming from the outside world This often has Orange White Green and Black wires Usually but not always Orange and...

Страница 6: ...5V electrolytic C9 1 Semiconductors 1N4004 diode D1 2 3 3 1N4148 D4 1 WO2 B1 2 3 3 Diode bridge MJE340 NPN transistor Q1 1 MPSA42 NPN transistor Q2 1 CM8870 datasheet from California Micro Devices www...

Страница 7: ...t we sell A relay is an electrically operated on off switch The voltage and current limits specified in the product documentation generally relate to resistive or light inductive loads Relay Terminals...

Страница 8: ...QUASAR CODES 3140 DTMF Telephone Relay Switcher Page 7...

Отзывы: