We would always advise users of the windows application to run the program as 
“administrator”. When starting the W016 program, right click on the program and select 
‘Run as administrator’ from the drop down list.  

EXAMPLE RELAY WIRING AND TEMPERATURE SETTINGS 

The W016 is designed primarily for a heating setup but can also be used for cooling. The wiring is 
different depending on whether you are using the relay for a heating or cooling function.  

 

Heating:  

Connect your heating equipment to the W016 in the 

normal open

 configuration as seen in the 

table below.  
In the Android APP, SETUP > RENAME: rename 

N.O.

 to ‘Heater ON’, and 

N.O.

 to ‘Heater OFF’. 

In the Android APP, SETUP > TEMPERATURE: set your temperature ranges. 

NO

: the lowest heating activation temperature. (when colder than ‘xx‘, turn on.) 

NC

: the highest heater operating temperature. (if warmer than ‘xx‘, turn off.) 

(The ON temperature must be at least 1°C lower than the OFF  temperature.) 

 

Cooling:  

For cooling, reverse the way the relays are wired. Connect your cooling equipment in the 

Normal 

closed

 configuration as seen in the table below.  

It is important to understand that relays wired in ‘normal closed’ position will operate in 

the opposite way than expected. In this setup off will turn the relay on. This needs to be 
taken into account during setup.

 

In the Android APP, SETUP > RENAME: rename 

N.C.

 to ‘Cooler ON’, and 

N.O.

 to ‘Cooler OFF’. 

In the Android APP, SETUP > TEMPERATURE: set your temperature ranges. 

NC

: the highest cooling activation temperature. (when warmer than ‘xx‘, turn on.) 

NO

:

 

the Lowest cooling operating temperature. (if colder than ‘ xx‘, turn off.)  

(The ON temperature must be at least 1°C lower than the OFF  temperature.)

 

Example setting and wiring to maintain temperature at 25-40°C  

 Connected Device

 

Heater

 

Cooler

 

APP ON-OFF settings

 

25°C -  

30°C

 

35°C 

- 40°C 

Relay configuration

 

 

 