background image

 

 

QK-A016 Manual                                                     

  

 

https://www.quark-elec.com

 

3  of  10 

2021 

V1.0 

1. Introduction 

The QK-A016 is a high precision battery monitor and can be used for boats, campers, caravans and 
other devices using a battery. The A016 measures the voltage, current, ampere-hours consumed and 
the remaining time at the current rate of discharge. It provides wide range of battery information. The 
programmable alarm allows user to setup the capacity/voltage warning buzzer.     

The A016 is compatible with most types of batteries in the market including: lithium batteries, lithium 

iron phosphate batteries

lead-acid batteries and nickel-metal hydride batteries. 

The A016 outputs the standard NMEA 0183 format messages so the current, voltage and capacity 
information can be combined with the NMEA 0183 system on the boat and shown on the supported 
Apps.   

2. Why a battery should be monitored?   

Batteries can be ruined by excessive discharge. They may also be damaged by under-charging. This 
may result in the battery performance being less than what is expected. Operating the battery without 
good metering is like running a car without any gauges.   

Apart from offering an accurate state of charge indication, the battery monitor can also help users how 
to get the best service life out of the battery. The service life of battery could be negatively affected by 
excessive deep discharging, under- or overcharging, excessive charge- or discharge currents and/or 
high temperatures. Users can detect such abuse easily through the display monitor of the A016. 
Ultimately the longevity of the battery can be extended which will result in long term savings.     

 
3. Connections and Installation 

Before starting the installation, ensure that no metal tool can cause a short circuit. Removing all 
jewellery such as rings or necklaces prior to any electrical work is considered best practice. If you 
believe you may not be sufficiently skilled to undertake this installation safely, please seek the 
assistance of a installers/electricians who are aware of regulations for working with batteries.   

Please strictly follow the orders of connections given below.   

Use a fuse of the correct value as shown in the following diagram.   

 

Figure 1 A016 wiring diagram

 

Содержание QK-A016

Страница 1: ...g time at the current rate of discharge and charge status NMEA 0183 format messages output Wide input voltage range 10 5V 100V Suitable for most types of batteries including lithium battery lead acid battery High current measurement resolution 0 01Amp with current shunt User programmable alarm function Contents Contents 1 1 Introduction 3 2 Why a battery should be monitored 3 3 Connections and Ins...

Страница 2: ... of 10 2021 V1 0 4 Display and Control panel 4 5 Setting up 5 5 1 Setup battery monitor parameters 5 5 2 Setup process 6 5 3 Backlight 6 5 4 Sleep mode in low power 6 6 NMEA 0183 output 6 7 Specifications 8 8 Limited Warranty and Disclaimer 8 ...

Страница 3: ...g less than what is expected Operating the battery without good metering is like running a car without any gauges Apart from offering an accurate state of charge indication the battery monitor can also help users how to get the best service life out of the battery The service life of battery could be negatively affected by excessive deep discharging under or overcharging excessive charge or discha...

Страница 4: ...he shunt to the positive terminal of the battery with a AGW22 18 wire 0 3 to 0 8mm 5 Connect the positive load to the positive terminal of the battery Using a fuse is highly recommended 6 Connect the positive charger terminal to the positive terminal of the battery 7 Connect the display with the shunt with the shielded wire 8 Double check all the connections with the above diagram before turning o...

Страница 5: ...arging The remaining time will be calculated from the residual capacity and the real current Battery symbol When the battery is being charged it will cycle to show it is filling When the battery is full the symbol will be shaded 5 Setting up 5 1 Setup battery monitor parameters The first time you use your A016 you will need to set the battery to its starting point at either empty or full capacity ...

Страница 6: ... V or LOW V only don t set the both value unless you clearly know the voltage characteristics of the battery 5 3 Backlight The backlight can be switched OFF or ON to save energy When the display works in the normal screen mode not setting up press and hold left key will switch the backlight between ON and OFF The backlight will flash during charge mode and light solid on during discharge mode 5 4 ...

Страница 7: ...ta 4 Units of measurement 5 Name of device fixed as A016 6 Checksum Example IIXDR U 12 10 V A016 CS the current voltage is 12 1V IIXDR I 2 1 A A016 CS the present current is 2 1Amp IIXDR G 64 0 A016 CS the current capacity remain is 64 0 The voltage current and capacity information can be shown via Apps on a mobile phone Android e g OceanCross The latest OceanCross can be download from https www q...

Страница 8: ... to the customer for parts and labour The customer is however responsible for any transportation costs incurred in returning the unit to Quark Elec This warranty does not cover failures due to abuse misuse accident or unauthorized alteration or repairs A returns number must be given before any unit is sent back for repair The above does not affect the statutory rights of the consumer This product ...

Страница 9: ...eated Blanket 4 2 6 7 A Laptop Computer 3 0 4 0 A Microwave 450W 40A Radar Antenna 3 0 A Radio 3 0 5 0 A Vent Fan 1 0 5 5 A TV 3 0 6 0 A TV Antenna Booster 0 8 1 2 A Toaster Oven 7 10 A LP Furnace Blower 10 12 A LP Refrigerator 1 0 2 0 A Water Pump 2 gal m 5 6 A VHF Radio transmit standby 5 5 0 1 A Vacuum 9 13 A Rating of Commonly used 230V AC Appliances inverted power from 12VDC battery typical v...

Страница 10: ...12 80V 13 00V 100 12 70V 12 80V 90 12 40V 12 50V 80 12 20V 12 30V 70 12 10V 12 15V 60 12 00V 12 05V 50 11 90V 11 95V 40 11 80V 11 85V 30 11 65V 11 70V 20 11 50V 11 55V 10 10 50V 11 00V 0 When the SOC falls below 30 the risk of damaging the battery is increased Therefore we advise to always keep the SOC above 50 to optimize the life cycles of the battery ...