Quantum Trinity F90+ Скачать руководство пользователя страница 1

It is saftey-relevant to strictly follow the Quick-Start-Guide

FLIGHT PLANNING

Weather conditions

• 

Wind ground: max. 9 m/s (17.5 kn) (see picture)

• 

Wind in flight: max. 12 m/s (23 kn) 

• 

Temperature: -12 °C to 50 °C (10.4 °F to 122 °F) 

• 

Do not fly in rain or snow.

 

Be aware that there is no software restriction between 

1500 m – 4000 m regarding the wind tolerance (ground).

0 m

2 m

(6.6 ft)

1500 m

(4921.3 ft)

3000 m

(9842.5 ft)

4500 m

(14763.8 ft)

4000 m

(13123.4 ft)

 

Wind tolerance (ground)   

 max. 9 m/s (17.5 kn)

 

Wind tolerance (ground)   

 max. 7 m/s (13.6 kn)

 

Wind tolerance (ground)   

 max. 5 m/s (9.7 kn)

Take-off MSL

Flight time

Wind speed

* Check the actual windspeed 
by using the anemometer at 2 m (6.6 ft) AGL

Maximum take-off and landing altitude (max. 4000 m / 13123.4 ft)

Maximum flight altitude (max. 4500 m / 14763.8 ft)

*

MODE

SET

*

MODE

SET

*

MODE

SET

 

Max. flight time  

 90 minutes

 

Max. flight time  

 90 minutes

 

Max. flight time  

 75 minutes

Check

Batteries

Charged

• 

UAV battery packs (fully charged)

• 

RC Transmitter

• 

Laptop

• 

Powerbank for iBase

Firmwares 

Updated

QBase software

Updated

Mission planning in QBase 3D

Check

UAV ASSEMBLY

Set up the laptop and open QBase

Check

Set up the QBase modem 

and connect it to the Laptop

Check

Set up the ADS-B receiver

Check

Set up the iBase 

• 

Micro SD-card is inserted

• 

Antenna center is exactly above the reference mark

• 

Not shaded by objects

• 

Stay away min. 5 meters

• 

Power bank is connected and powered 

• 

iBase is recording (blue LED blinking)

Check

Turn on the RC Transmitter

Check

Check the UAV for damages 

(e.g. surfaces, propeller)

Check

Magnetometer Calibration 

(If required)

• 

Obligatory: flight location > 50 km away from the last flight location 

• 

 Calibration and take-off area is free of metal (parking decks, cars, metal structures) or  

any devices causing electric or magnetic fields (power lines, generators, mobile phones)

Calibrated 

 

to location

All parts assembled and locked

Check

Remove the payload transport lock

Check

Battery pack is connected 

(UAV will start automatically)

Check

Take-off position

• 

Take-off from the UAV transportation box.

• 

Optional: Cover the ground with a canvas cover. 

Fix it with weights.

Check

TAKE-OFF

RC and QBase Modem connection

Established

Camera detected

• 

Camera > Trigger: Triggers and exposures count up in QBase and on the RC

Check

QBase final Check

Obstacle clearance in reality

• 

No obstacle within a radius of 20 m around Home Waypoint

• 

Re-/transition, descent circle, flight paths: altitude 20 m higher than obstacles

Check

UAV heading

• 

Ensure the direction of the displayed UAV corresponds with the direction of the UAV on the ground 

• 

Do not fly if the heading on the ground is not correct: 

critical deviation ≥ 10°

Check

Trinity F90+

QUICK-START-GUIDE

Отзывы: