Redundant and non-redundant components
In storage area network technology, redundancy means that essential services are implemented using
duplicated components in such a way that if one component fails, an alternative component continues
to provide the service. This redundancy ensures the availability of data in case a component fails.
In most RAID systems, most of the components are redundant, but the system might not be fully
redundant. In other words, there might be one or two components whose individual failures would
cause loss of access to data. Therefore, a
fully redundant system duplicates all components and is
configured to make sure that the duplicate components can be accessed in case of a failure. The
manner in which the system is cabled is an essential component of creating a successfully configured
redundant system.
Single point of failure
Any component or path that is not duplicated (redundant) or whose failure can cause loss of data
access is called a potential
single point of failure. The cabling scenarios in this document note the
components that present a potential single point of failure. Choose a cabling topology that does not
create a single point of failure.
SFP transceivers, fiber-optic cables, and copper cables
Fibre Channel host connections use fiber-optic cables. If your system will be connected with Fibre
Channel fiber-optic cables, you must install an active SFP transceiver (for Fibre Channel) into each
port in which a fiber-optic cable will be connected before you plug in the fiber-optic cable.
Connections for 10-Gb/s iSCSI use copper or optical cables with SFP transceivers. Connections for
1-Gb/s iSCSI use copper cables with RJ-45 connectors and do not require SFP transceivers.
Connections for SAS use copper or optical cables with SFF 8088 or SFF 8644 connectors and do not
require SFP transceivers.
Infiniband host connection support fiber-optic and copper cables with integrated QSFP transceivers.
Connections for 25Gb/s iSCSI, use copper or optical cables with SFP28 transceivers.
The following figures show the two types of cables that use SFP transceivers. Note that your SFP
transceivers and cables might look slightly different from the ones shown. The differences do not
affect the performance of the SFP transceivers.
Caution:
Risk of exposure to laser radiation – Do not disassemble or remove any part of a Small
Form-factor Pluggable (SFP) transceiver because you might be exposed to laser radiation.
10 |
Содержание StorNext QD7000
Страница 1: ...Hardware Cabling Guide StorNext QD7000 Firmware 8 40 xx xx 6 68683 01 Rev A...
Страница 7: ...Preface Hardware Cabling Guide vii...
Страница 10: ...E Series Hardware Cabling Guide December 2017 215 11792_B0 doccomments netapp com...
Страница 11: ......
Страница 90: ...One E5660 controller drive tray and one DE6600 drive tray Drive shelf or drive tray cabling 81...
Страница 106: ...One E2760 controller drive tray and one drive tray Drive shelf or drive tray cabling 97...