background image

ELM2L

EMERGENCY LIGHTING UNIT

“TEST” button /

Status Indicator

Press latches to disengage 

housing from mounting plate

Remote test option

Installation and wiring …………………..…………......…………………………………… P. 2-3
Testing and maintenance ………...…………………………………………………………P. 4-5

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions 

should always be followed, including the following:

!
!

!

!

!

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WARNING: 

FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH, SERIOUS INJURY OR

SIGNIFICANT PROPERTY DAMAGE

- For your protection, read and follow these warnings and instructions carefully before installing or 

maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand 

these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.

WARNING:

RISK OF ELECTRIC SHOCK – NEVER CONNECT TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS 

ENERGIZED

.

WARNING:

DO NOT USE ABRASIVE MATERIALS OR SOLVENTS. USE OF THESE SUBSTANCES MAY DAMAGE FIXTURE, 

WHICH MAY RESULT IN PERSONAL INJURY.

WARNING

RISK OF PERSONAL INJURY – This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing

from carton, handling, installing and maintaining this product.

WARNING: 

The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not disassemble, heat above 70° C    

(158° F), or incinerate. Replace battery only as directed on the battery label and page 5 of these instructions. Use of unauthorized battery voids 

warranty and UL listing of this product, and may present a risk of fire or explosion.

•Disconnect A.C. power before servicing.

•All servicing should be performed by qualified personnel.

•Consult your local building code for approved wiring and installation.

•Do not use outdoors unless used with Acuity Brands accessories appropriate to the application.

•Do not mount near gas or electric heater.

•Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.

•The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

•Do not use this equipment for other than intended use.

SAVE THESE INSTRUCTIONS

AND DELIVER TO OWNER AFTER INSTALLATION

NOTE:

Product versions that comply with CA Title 20 are marked  BC  on the product label.

Содержание ELM2L

Страница 1: ...URY WARNING RISK OF PERSONAL INJURY This product may have sharp edges Wear gloves to prevent cuts or abrasions when removing from carton handling installing and maintaining this product WARNING The ba...

Страница 2: ...2 or Figure 3 Remove U shaped knockout from top center of housing Hint Use a pair of wire cutters first to start a cut in the thick portion at each side of the knockout then finish breaking it out wit...

Страница 3: ...y vary Connect the polarized battery plug to the charger board Make certain that the battery cable is routed to avoid interference with the AC input connector or other components Federal Communication...

Страница 4: ...enever the total connected lamp load of the unit is changed or a lamp is replaced NOTE Manual load learning functions cannot be initiated if there is inadequate charge in the batteries If this is so w...

Страница 5: ...ently bend the snap at each side of the collar outward to release the lamp assembly Cut wires near lamp board and strip back 1 4in Connect stripped wires to the replacement lamp following the yellow b...

Страница 6: ...Part 912 00026 002 Rev C 1 15 2018 Acuity Brands Lighting Inc 2018 All Rights Reserved LIFE SAFETY SOLUTIONS TEL 800 334 8694 www lithonia com...

Страница 7: ...o puede tener bordes afilados Use guantes para evitar cortes o abrasiones al extraer el producto de la caja manipularlo instalarlo o repararlo ADVERTENCIA La bater a utilizada en este dispositivo pued...

Страница 8: ...s ranuras de manera que los conectores est n asegurados como se muestra en las figuras 2 o 3 Retire el agujero troquelado en forma de U de la parte superior central de la carcasa Sugerencia Utilice pr...

Страница 9: ...necte el enchufe de la bater a polarizado a la placa del cargador Aseg rese de verificar el recorrido del cable para evitar interferencias con el conector de entrada de CA o con otros componentes Requ...

Страница 10: ...ad de la l mpara conectada est totalmente cargada o que una l mpara sea reemplazada NOTA Las funciones de aprendizaje de carga manuales no pueden iniciarse si las bater as no tienen carga suficiente S...

Страница 11: ...cuidado el encaje en cada lado del cuello hacia afuera para liberar el ensamblaje de la l mpara Corta los cables cerca de la placa de la l mpara y tira hacia atr s 1 4in Conecte los cables pelados a l...

Страница 12: ...N de pieza 912 00026 002 Rev C 1 15 2018 Acuity Brands Lighting Inc 2018 Todos los derechos reservados SOLUCIONES DE SEGURIDAD PERSONAL TEL FONO 800 334 8694 www lithonia com...

Отзывы: