Chapter 3: DXi6902 FRU Removal and Replacement Procedures
Replacing Node Power Supplies
Quantum DXi6902 User’s Guide
93
Figure 50 Node Power Supply
LED
Removing a Failed Power Supply from the Node
To remove the failed power supply from the DXi6902 Node:
Caution:
Make sure to remove the failed power supply (amber or
dark LED handle) and not the functioning power supply
(green LED handle). If you remove the functioning power
supply, power will be lost to the Node, and data loss may
occur.
1
Disconnect the power cable from the power source and the failed
power supply (see
2
Remove the power cable from the strap.
3
Press the release latch and slide the power supply out of the chassis.
Power supply status
indicator/handle