Chapter 3 Media Changer Commands
Inquiry Command (12h)
42
Quantum ATL SuperLoader Software Interface Guide
The following table describes the identifiers supported by the
SuperLoader.
Table 13 Supported
Identifiers
Command Support
Data
3
An application client can request command support data by
setting the CmdDt bit of the INQUIRY command to 1, and
specifying the SCSI operation code of the Command Descriptor
Block (CDB) for which it wants information.
The format of the command support data and definitions of the
fields follow.
Value
Description
1
Concatenation of the Vendor Name,
Product ID, and unit serial number
2
Canonical form of the IEEE Extended
Unique Identifier, 64 bit (EIU-64)
3
FC-PH Name_Identifier
Identifier
Identifier data, based on the Identifier Type.
Identifier
Type
Code
Set
Length
Identifier
1
2
24
QUANTUM UHDL, 12 ASCII space
characters (20h), followed by the unit
serial number in ASCII.
2
1
8
8 bytes of binary data indicating the
EUI-64 assigned to the drive.
3
1
8
8 bytes of binary data indicating the
64-bit, type 3, FC-PH Name_Identifer
assigned to the drive.
Field Name
Field Description
Содержание ATL SuperLoader ATL
Страница 1: ...ATL SuperLoader DLT and ATL SuperLoader LTO Software Interface Guide 81 60220 01 A02...
Страница 18: ...Preface Document Conventions xviii Quantum ATL SuperLoader Software Interface Guide...
Страница 26: ...Chapter 1 Theory of Operation Automatic Drive Cleaning 8 Quantum ATL SuperLoader Software Interface Guide...
Страница 44: ...Chapter 2 Messages Supported SCSI Messages 26 Quantum ATL SuperLoader Software Interface Guide...
Страница 192: ...Chapter 3 Media Changer Commands Write Buffer Command 3Bh 174 Quantum ATL SuperLoader Software Interface Guide...
Страница 196: ...Index 178 Quantum ATL SuperLoader Software Interface Guide...