ActiveScale™ P100E3 Support Guide
14
3. Remove the necessary drives from the drive tray.
Important:
If you remove more than one drive, record the order that the drives
were removed so that they can be placed back in the proper location. Consider
labeling each drive.
a. Locate the drive carrier handle release button.
b. Press the release button and swing the drive carrier handle upward.
Figure 3
-
5. Drive handle operation
The drive is now free from the tray and can be removed.
Repeat these steps for all required drives. If you are removing drives as part of a Storage Node
replacement, remove all of the drives. If you are returning a faulty drive, record the serial number for
return purposes.
-
3.1.1.3 Installing a 3.5 inch drive
To install a replacement 3.5 inch drive:
1. Position the drive carrier handle on the replacement drive in the upward position.
2. Align the drive in the drive tray with the power and data connectors facing toward the rack and set it
in the drive tray.
3. Swing the drive carrier handle down. The drive should slide into place and there should be a click
when the drive is secured.
4. Slide the drive tray back into the system.
5. Check to make sure that the drive has been reintegrated and the status is
Online
. If the status is
Degraded
,
Decommissioning
, or
Decommissioned
, wait for approximately 15 minutes and check