10
Balancing
The Quanser Aero 2 should be balanced before running any of the experiments. There are two tungsten
weights mounted on each rotor that can be adjusted to balance the system, as shown in Figure 6.
Figure 6. Mass sliders for leveling the Aero 2 unit
Start by moving the sliding masses all the way outwards. If the Aero 2 is not balanced, identify the rotor that
is leaning downwards. Move the mass slider on this rotor inwards until the system is balanced.
Environmental
The Quanser Aero 2 is designed to function under the following environmental conditions:
●
Standard rating
●
Indoor use only
●
Atmospheric conditions
○
Temperature - 15
◦
C to 35
◦
C
○
Altitude - up to 2000 m
○
Relative humidity - 30% to 60%
○
Air Pressure
–
86 kPa (860 mbar)
–
106 kPa (1060 mbar)
●
Pollution Degree 2
●
Mains supply voltage fluctuations up to 10% of nominal voltage
●
Maximum transient overvoltage 2500 V