I
KPC-1561 User’s Manual
KPC-1561
15” Fanless Industrial Panel PC with Dual Core Intel
®
Atom™ Processor D2550 + Intel
NM10 Express Chipset
User’s Guide
Страница 1: ...I KPC 1561 User s Manual KPC 1561 15 Fanless Industrial Panel PC with Dual Core Intel Atom Processor D2550 Intel NM10 Express Chipset User s Guide...
Страница 2: ...se This Guide 8 Unpacking 8 Regulatory Compliance Statements 8 Maintaining Your Computer 9 Chapter 1 Introduction 11 Overview 11 Product Specifications 12 System tour 13 Mechanical Dimensions 15 Chapt...
Страница 3: ...u Power Management Configuration 28 Table 6 Advanced Menu CPU Advanced Configuration 29 Table 7 Advanced Menu SATA Configuration 29 Table 8 Advanced Menu PCI BUS Driver Version V 2 05 02 30 Table 9 Ad...
Страница 4: ...Figures Tables 4 KPC 1561 User s Manual Table 17 Advanced Menu H W Monitor 38 Table 18 Boot Menu 39 Table 19 Security Menu 40 Table 20 Save Exit Menu 40...
Страница 5: ...installation instructions in this user s guide for precautions and procedures If you have any questions please contact our Post Sales Technical Support Access can only be gained by service persons or...
Страница 6: ...aligned to avoid bending any connector pins Also before connecting a cable make sure both connectors are correctly oriented and aligned CAUTION Do not attempt to service the system yourself except as...
Страница 7: ...t handle or store system boards near strong electrostatic electromagnetic magnetic or radioactive fields Instructions for Lithium Battery WARNING Danger of explosion when battery is replaced with inco...
Страница 8: ...ces FCC Compliance Statement This equipment has been tested and found to comply with limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reaso...
Страница 9: ...sed Consideration should be given to the maximum rated ambient temperature Overheating can cause a variety of problems including premature aging and failure of chips or mechanical failure of devices I...
Страница 10: ...e conditioners keep a system s AC power source voltage at a fairly constant level and therefore can handle brownouts Because of this added protection line conditioners cost more than surge protectors...
Страница 11: ...t thus easily meeting a broad range of customer requirements The KPC series provide a compact high performance human machine interface with optimal shock vibration and temperature resistance for tough...
Страница 12: ...HDMI 1x VGA LAN 2x Gigabit Ethernet Realtek RTL8111E PXE WOL supported Audio Realtek ALC662 HD Codec w 2W Audio Amplifier Mic In Line In Line Out Supported Storage 1x 2 5 SATA HDD or SSD space USB 4 x...
Страница 13: ...o run simultaneously on a single computer with some peripheral acting as additional plug in sites or hubs Power Switch The power switch allows powering ON and OFF the system Ethernet The eight pin RJ...
Страница 14: ...headphone jack is used to connect the system s audio out signal to amplified speakers or headphones MIC IN Pink The microphone jack is designed to connect the microphone used for video conferencing vo...
Страница 15: ...Chapter 1 15 KPC 1561 User s Manual Mechanical Dimensions 409 99 x 315 x 82 46 mm W x D x H Figure 2 Mechanical Dimensions...
Страница 16: ...Chapter 2 16 KPC 1561 User s Manual Chapter 2 Getting Started Setting up your PC Connecting the monitor Connect the VGA HDMI cable from your display to the VGA HDMI port Figure 3 VGA HDMI VGA HDMI...
Страница 17: ...your computer Figure 4 Connect USB mouse keyboard NOTE Using a third party USB mouse or keyboard may require software drivers Check the manufacturer s website for the latest software drivers Connectin...
Страница 18: ...B2 RXD RX NA RX B3 TXD TX DATA TX B4 DTR RX NA RX B5 GND GND GND GND B6 DSR NA NA NA B7 RTS NA NA NA B8 CTS NA NA NA B9 RI NA NA NA Port Pin RS 232 RS 422 Half Duplex RS 485 Full Duplex RS 485 2 A1 DC...
Страница 19: ...nual COM3 COM6 Pin Signal 1 DCD Data carrier detect 2 RXD Receive data 3 TXD Transmit data 4 DTR Data terminal ready 5 GND ground 6 DSR Data set ready 7 RTS Request to send 8 CTS Clear to send 9 RI Ri...
Страница 20: ...Connect the power adapter cable to the DC jack DC IN of the KPC 1561 2 Connect the power cable to the power adapter 3 Connect the power cable to a power outlet 4 Press the power switch on the front p...
Страница 21: ...FDMI 75 100 standard mounting holes as shown below Use 4 screws with the appropriate length for your mounting bracket Figure 8 VESA Mounting Hole Locations NOTE To fasten the metal shelf your monitor...
Страница 22: ...l Mounting The Panel PC can be panel mounted and comes with brackets and screws for this purpose The required cutout for panel mounting and maximum panel thickness is shown below Figure 9 Panel Mount...
Страница 23: ...Chapter 2 23 KPC 1561 User s Manual Below are the demonstrations of how to do panel mounting Step1 Tightening the screws as shown right Step2 Done Figure 10 Panel Mounting...
Страница 24: ...se contact us AMI s ROM BIOS provides a built in Setup program which allows the user to modify the basic system configuration and hardware parameters The modified data will be stored in a battery back...
Страница 25: ...gate between menu screens Table 2 BIOS Main Menu BIOS SETUP UTILITY M a i n A d v a n c e d B o o t S e c u r i t y S a v e E x i t Product Information Select Screen 6HOHFW WHP Enter Select Change Opt...
Страница 26: ...board LAN2 Controller Enabled Onboard LAN2 Boot Disabled Audio Controller Enabled Display Configuration Power Management Configuration CPU Advanced Configuration SATA Configuration PCI Subsystem Setti...
Страница 27: ...F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Fixed Graphics Memory Size 128 MB IGFX Boot Type VBIOS Default Active LVDS No LVDS Version 2 14 1219 Copyright C 2011 Am...
Страница 28: ...S3 By PS 2 Mouse Disabled Resume By PCIE Device Disabled Resume By RTC Alarm Disabled EUP Power Saving Mode Disabled Watchdog Timer Configuration Version 2 14 1219 Copyright C 2011 American Megatrend...
Страница 29: ...Enabled Limit CPUID Maximum Disabled EIST Enabled Version 2 14 1219 Copyright C 2011 American Megatrends Inc Hyper Treading Options Disabled Enabled Execute Disable Bit Options Disabled Enabled Limit...
Страница 30: ...ts F4 Save Exit ESC Exit PCI Latency Timer 32 PCI Bus Clocks VGA Palette Snoop Disabled PERR Generation Disabled SERR Generation Disabled Version 2 14 1219 Copyright C 2011 American Megatrends Inc PCI...
Страница 31: ...P Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit USB Devices 1 Keyboard 1 Mouse Legacy USB Support Enabled EHCI Hand off Disabled Version 2 14 1...
Страница 32: ...Inc Table 11 Advanced Menu Super IO Configuration Serial Port 1 Configuration BIOS SETUP UTILITY M a i n Ad v a n c e d B o o t C h i ps e t P o w e r S e c u r i t y E x i t Serial Port 1 Configurat...
Страница 33: ...3 Change Settings IO 2F8h IRQ 3 Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 Amer...
Страница 34: ...ettings IO 2F8h IRQ 3 4 5 Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Me...
Страница 35: ...ettings IO 2F0h IRQ 3 4 5 Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Me...
Страница 36: ...ettings IO 2E0h IRQ 3 4 5 Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Me...
Страница 37: ...ettings IO 3E8h IRQ 3 4 5 Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 14 1219 Copyright C 2011 American Me...
Страница 38: ...us Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit CPU Warning Temperature Disabled CPU Temperature 32 SYS Temperature 4...
Страница 39: ...eneral Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Full Screen LOGO Display Disabled Setup Prompt Timeout 1 Bootup NumLock State On Boot Option Priorities Boot Option 1 UEFI Sa...
Страница 40: ...um Length 3 Maximum length 20 Administrator Password User Password HDD Security Configuration HDD 0 FUJITSU MHZS2 Select Screen 6HOHFW WHP Enter Select Change Opt F1 General Help F2 Previous Values F3...
Страница 41: ...S asks for a confirmation before exiting Discard Changes Discards changes done so far to any of the setup values This option allows you to discard the selections you made and restore the previously sa...
Страница 42: ...operating system and the necessary drivers to operate it After you have finished assembling your system and connected the appropriate power source power it up using the power supply and install the de...