DISPLAY
LCD CODE
Description
TAMPER
Attempt to fraud or in other ways affect the meter's behavior.
LEAK
Possible medium leakage detected.
BURST
Possible large leakage detected.
REVERSE
Water is flowing through the meter in the wrong direction.
NO SENSING
Unable to detect water. May be due to the pipe not being filled with water, or a
loosely installed meter. Flow is not measured.
Indicates the current direction of the water flow (left or right).
Indicates a faulty metering device, or shows a warning together with an
error/warning code.
Indicates successful radio transmissions. A single dot indicates a faulty radio
module.
Low battery, less than 180 days remaining.
The units perform an LCD check every 5 minutes where all segments are blank for 1s and then all
segments displayed for 1s as a visual verification of the LCD screen’s full functionality.
The following information is then displayed in the following order, 1s per item:
●
Firmware version number
●
Firmware CRC32 checksum in hexadecimal format
●
Current pipe temperature in °C
●
Selected pipe setting type
●
Event/changelog counter
●
If applicable, the last error code logged