QUALISYS Q ACADEMY AMTI GEN 5 Скачать руководство пользователя страница 1

 

 
 
 

 
 

 

QUALISYS AB 

Kvarnbergsgatan 2 · 411 05 Gothenburg · SWEDEN 

Tel. +46 31 336 94 00 · Fax +46 31 336 94 20 

[email protected] · www.qualisys.com 

Содержание Q ACADEMY AMTI GEN 5

Страница 1: ...QUALISYS AB Kvarnbergsgatan 2 411 05 Gothenburg SWEDEN Tel 46 31 336 94 00 Fax 46 31 336 94 20 sales qualisys com www qualisys com...

Страница 2: ...ra system For advanced settings beyond the scope of this tutorial please refer to your QTM manual or to your AMTI documentation CONTENTS DOWNLOADING THE GEN 5 DRIVER 2 CONNECTING THE GEN 5 4 Computer...

Страница 3: ...current project 2 In QTM open Project Options either by clicking the gear icon near the top left of your screen or by typing the keyboard shortcut Ctrl W 3 With the Input Devices window open click Dow...

Страница 4: ...DRIVER 3 5 The drivers will be in a compressed folder so you will need to extract the contents 6 Follow the extraction instructions choosing a location on your computer that you will remember later o...

Страница 5: ...e flat rectangular end into your computer Camera system to Gen 5 To synchronize the force plate data with your Qualisys camera system you will need to use the Sync Trig splitter a short cable with a s...

Страница 6: ...hen you plug in the amplifier If it doesn t open Device Manager right click on Gen 5 and click on Update Driver Software Installing the driver 1 With the Update Driver Software window open on your com...

Страница 7: ...adjust the amplifier s settings 1 Open Project Options as before by clicking the gear icon near the top left of your screen or by typing the keyboard shortcut Ctrl W 2 In the Input Devices window you...

Страница 8: ...mera 5 It is recommended to zero your force plate s before each trial and you can automate this by selecting one or both of the checkboxes under Force plate auto zero 6 Click OK to save your settings...

Страница 9: ...sing click on the plus sign next Force Data and then on Amti Gen 5 2 Next click on Calibration to input the force plate calibration parameters length width offsets calibration matrix etc according to...

Страница 10: ...plate often determines the origin point for calibration The L frame is a tool that defines the X Y and Z axes of the volume during calibration and its corner sets the origin point Many labs choose to...

Страница 11: ...orners of your force plate 2 With QTM open start a new session by clicking on the blank paper icon in the top left or by using the keyboard shortcut Ctrl N 3 Your screen will automatically display the...

Страница 12: ...m all 7 Drag them into the empty right pane called Labeled trajectories Identifying the location in QTM 1 Open Project Options as before by clicking the gear icon near the top left of your screen or b...

Страница 13: ...ll not automatically know which direction the force plate is oriented and it will give more than one possible solution Click OK to select between them 5 The easiest way to choose between the orientati...

Страница 14: ...type 3 and you will see a 3D view of the force plate 3 One way to test is to step on one end of the force plate while keeping an eye on your computer screen The force arrow should point toward you An...

Страница 15: ...THE FORCE PLATE IN THE VOLUME 14 5 At the bottom left of the window that opens click Rotate 180 degrees Click OK to save 6 Retest as above to confirm that the force plate is now oriented correctly wi...

Страница 16: ...Pressure threshold and then set the minimum amount of vertical force required to activate the force plate s data recording Keep in mind that any forces below this threshold will not be recorded so thi...