Figure 4.1 Junction Box Cover Plate (Right side shown)
NOTICE:
You will need to supply: 14-2 wire with ground
and wire nuts.
• Remove junction box cover plate on the bottom right
side of the fireplace to access the outlet wires. See
Figure 4.1 & 4.2. NOTE: The power may enter from
either side by switching the cover plates on the outer
shell and switching the outlet plate in the bottom access
area to the other side. See Figure 4.4.
• Attach the romax connector to the cover plate and insert
the 14-2 WG through it and make the wire connections.
• Match colors to wire harness, black to black, white to
white, green to green (ground) and secure with wire nuts.
•
Install cover plate. See Figure 4.3.
NOTICE:
Wiring for fireplace must be done before framed
enclosure is completed. If using a Heat Zone kit, it also must
be installed before enclosure is complete.
4
Electrical Wiring
A. Fireplace
B. Thermostat Installation
The kit comes with a programmable wall thermostat
(C1)
and 25 ft. of thermostat wire
(C2)
. If you need to run more
than 25 ft. make sure you use a continuous strand of 18 to
22 gauge thermostat wire. For optimum performance your
thermostat should be:
•
Mounted on an inside wall, approximately 5 ft. above
the floor
• Do not locate where there is poor air circulation such
as in a corner, alcove, behind doors, bookcase or
other objects
•
Located away from drafts, direct sunlight, above a
lamp, television, radiator, a wall next to a window, or
direct heat from the appliance
• Avoid damp environments as this can lead to corrosion
that may shorten thermostat life
• If painting or construction work around, cover the
thermostat completely or wait until work is complete
before installation.
Outer cover plate for
thermostat wire
Figure 4.5 Left Side Shown
Junction box cover
plate may be
switched to the
left side.
For left side install
remove outlet/plate and
switch it out with the
inner thermostat cover
plate on the left side.
Outer plate
Power cord for control
board
Figure 4.4 Junction Box Shown on Right Side
•
The thermostat wire will be installed on the opposite
side of where the electric comes in at. See Figure 4.5.
Junction
box wires
Figure 4.2 Junction Box Wires
Figure 4.3
White
Black
14-2 w/ground (110v)
incoming power
From
junction box
23