B. Clearances to Combustibles (UL and ULC)
Installations with
3 to 3 inch Top Vent Adapter
Installations with
3 to 6 inch Offset Adapter
NOTE:
• Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual
design preference.
Straight Back Against Wall
Inches
Millimeters
A
Back Wall to Appliance
3
76
B
Side Wall to Appliance
9
229
Corner Installation
Inches
Millimeters
C
Walls to Appliance
3
76
Table 11.1
Vertical Installation
Inches
Millimeters
D
Back Wall to Pellet Pipe
3
76
E
Side Wall to Appliance
9
229
F
Back Wall to Appliance
7-5/8
194
Corner Installation
Inches
Millimeters
G
Walls to Appliance
3
76
Table 11.2
Vertical Installation
Inches
Millimeters
D
Back Wall to Pipe
3
76
E
Side Wall to Appliance
9
229
F
Back Wall to Appliance
10-1/4
260
Corner Installation
Inches
Millimeters
G
Walls to Appliance
3
76
Table 11.3