Page 12
7075-205B
October 12, 2015
Voyageur Grand
D. Blower Replacement
1. The grille on the blower access assembly is hinged.
Swing the grille downward to expose the 2 screws.
Figure 8.1
2. Remove the 2 screws from the blower access assembly
and slide assembly away from the appliance.
3. Disconnect the wires from the blower.
4. Remove the 2 screws from the hold down bracket and
pull the blower and bracket forward.
5. Remove the blower from the hold down bracket.
6. Remove the protection guards from each end of the
blower.
7. Re-install in reverse order. Be certain that the hold down
bracket’s screws are completely seated in the grom-
ments. Insert the locating tab in the hold down bracket
into the placement slot.
Shock Risk
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
CAUTION
Figure 8.1
Do NOT allow hot coals or embers to overfl ow ash lip
•
May melt protective wire coating on fan power
cord causing electrical short, fi re or injury
Fire Risk
WARNING
Blower Access
Assembly
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Hold Down
Bracket
Remove Screws from Hold
Down Bracket and Pull
Forward
Placement Slot
CAUTION! Unplug appliance
from power source before
replacing any components.