Quadra-Fire  •  GARN-MBK-IPI-B, GARN-DPMH-IPI-B, GARN-DMBK-IPI-B, GARN-DCSB-IPI-B Installation Manual  •  2345-983_R2  •  07/15

52

B.  Vent Components List 

(Cont)

* Stove Adaptor Kit (Vertical Cap Kit) Includes 30’-4” flex, adapters, wall thimble, masonry, ZC flashing, 991DA vertical cap

NOTES: 

1

BeFoRe CuttING ANy hoLeS CheCK pIpe mANuFACtuReRS CuRReNt INStRuCtIoNS.

2

eACh pIpe mANuFACtuReR hAS theIR owN LISt oF pARtS FoR KItS.

3

SL IS NOT INTERChANGEABLE WITh SLP.

Description

HHt SL-P

M= Multi Pack (6)

Simpson

Dura-Vent

DirectVent Pro

Icc

chimney

45° Elbow, Swivel, Black

-

46DVA-E45B

-

90° Elbow, Galvanized

SLP90M

See Swivel

4DE90

90° Elbow, Swivel, Galvanized

-

46DVA-E90

-

90° Elbow, Swivel, Black

-

46DVA-E90B

4DE90B

Adjustable Flashing, 0/12-6/12

SLP-RF6M

46DVA-F6

4FA

Adjustable Flashing, 7/12-12/12

SLP-RF12M

46DVA-F12

4FB

Attic Insulation Shield - Cold Climates 36”

-

-

-

Attic Insulation Shield 12”

SLP-AS2M

-

-

Attic Insulation Shield, Adjustable 11”-20”

-

46-DVA-IS

4AS

Cathedral Support Box

SLP-CCS-BK

46DVA-CS

4SS

Ceiling Support

-

46DVA-DC

4CS

Co-Axial to Co-Lineal Appliance Connector

-

46DVA-GCL

CAA

Decorative Ceiling Firestop - Black

SLP-DCF-BK

-

4TR

Decorative Radius Cover

DRC-RADIUS

-

-

Firestop Spacer/Ceiling Firestop

SLP-FSM

46DVA-FS

-

Flex Trap Cap with Firestop

SLP-FLEX-TRAP

-

-

Flex Trap Cap with Firestop and 30’ Flex Pipe

SLP-FLEX-TRAP30

-

-

Masonry Chimney Conversion Kit

-

46DVA-KMC

-

Offset Support

-

46DVA-ES

OS

Offset Wall Thimble, Black

SLP-WT-BK

-

-

Silicone Roof Flashing, 4” to 8” pipes (6)

RF4-8M

-

-

Storm Collar

SLP-SCM

46DVA-SC

SC

Trim Plate, Black

-

-

4TP

Wall Support Band

SLP-HVSM

46-DVA-WS

WS

Wall Thimble Support Box/Ceiling Support

-

-

4WT

Wall Thimble, Black

SLP-WSM

46DVA-WT

-

tERMINAtIoN cAPS & KItS

Basic Horizontal Termination Kit (A)

-

46DVA-KHA

-

Chimney Liner Termination Kit

-

46DVA-GK

-

Horizontal Square Termination Cap

SLP-HHW2

46DVA-HC

HT

RHVK Snorkel Kit

-

844-8921

-

Snorkel Termination 14”

SLK-SNKD

46DVA-SNK14

ST14

Snorkel Termination 36”

-

46DVA-SNK36

ST36

*Stove Adaptor Kit (Vertical Cap Kit)

LINK-STOVE

-

-

Trapezoid Termination Kit (3-1/8”-4-3/4”)

SLP-TRAP1

-

-

Trapezoid Termination Kit (5-1/4” X 9-1/4”)

SLP-TRAP2

-

-

Vertical Termination Cap

SLP-TVHW

46DVA-VCH

VT

Содержание GARN-DCSB-IPI-B

Страница 1: ...or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to do if you smell gas DO NOT try to light any appliance DO NOT touch any electrical switch d...

Страница 2: ...ombustibles 8 C Hearth Extension Floor Protection 8 4 Termination Location and Vent Information A Vent Termination Minimum Clearances 9 B Chimney Diagram 10 C Approved Pipe 11 D Use of Elbows 12 E Mea...

Страница 3: ...of flashing installed and sealed ___________________________ Electrical Section 8 Pg 35 39 Unswitched power 110 120 VAC provided for the appliance ___________________________ Switch wires properly ins...

Страница 4: ...t ratings are certified without a reduction of input rate for elevations up to 4500 feet 1370 m above sea level Please consult provincial and or local authorities having jurisdiction for installations...

Страница 5: ...the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Note The...

Страница 6: ...e dry B Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measure Framing material Pliers Hammer Phillips screwdrive...

Страница 7: ...ctual appliance dimensions Use for reference only Figure 3 1 Appliance Dimensions Location Inches Millimeter Location Inches Millimeter A 17 7 8 454 E 18 1 8 451 B 15 3 8 391 F 17 3 8 441 C 23 5 8 600...

Страница 8: ...C A G A G C Hearth Extension Floor Protection CAUTION Risk of Fire or Injury Install appliance on a stable level platform or floor strong enough to support appliance without tipping A non combustible...

Страница 9: ...ENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 4 Termination Location and Vent Information Fire Risk Maintain vent clearance to combustibles as specified DO NO...

Страница 10: ...HERE TERMINAL IS NOT PERMITTED O N P R Q Electrical Service V K V K V L C V QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QM...

Страница 11: ...CATED VENTING COMPONENTS This product is approved to be vented either horizontally through the side wall or vertically through the roof You may vent through a Class A or masonry chimney if an approved...

Страница 12: ...286 Figure 4 5 Vertical and Horizontal Offset for SLP Elbows Vent Type X Y Inches Millimeters Inches Millimeters SLP 5 127 11 3 4 298 SLP Pipe Effective Length Rise Run Inches Millimeters Inches Milli...

Страница 13: ...ed horizontally See specific vent diagrams When penetrating a combustible wall a wall shield firestop must be installed When penetrating a combustible ceiling a ceiling firestop must be installed F Ve...

Страница 14: ...K IPI B GARN DPMH IPI B GARN DMBK IPI B GARN DCSB IPI B Installation Manual 2345 983_R2 07 15 14 Rear Vent Horizontal Termination Figure 4 7 No Elbow H1 Natural Gas Propane H1 14 in 356 mm Maximum H1...

Страница 15: ...ARN DMBK IPI B GARN DCSB IPI B Installation Manual 2345 983_R2 07 15 15 Rear Vent Horizontal Termination continued Figure 4 8 Back to Back 90 Elbows Only H1 24 in 610 mm Maximum H1 Note This configura...

Страница 16: ...e adjusted as vertical dimension increases 2 Elbows to Max Horizontal V1 Minimum H1 Maximum H1 H2 Maximum 2 ft 61 m 8 in 203 mm 18 in 46 m 4 ft 1 2 m 8 in 203 mm 3 ft 3 in 1 m 6 ft 1 8 m 8 in 203 mm 6...

Страница 17: ...as vertical dimension increases Note For optimum flame appearance air shutter may need to be adjusted as vertical dimension increases 3 Elbows to Max Horizontal V1 Minimum H1 Maximum HTotal 6 ft 1 8...

Страница 18: ...nt Vertical Termination One Elbow Figure 4 11 H1 V1 H1 Minimum H1 Maximum V1 Minimum V1 Maximum 6 in 152 mm 14 in 357 mm 6 ft 1 8 m 25 ft 7 6 m Note Flue restrictor may need to be adjusted as vertical...

Страница 19: ...flame appearance air shutter may need to be adjusted as vertical dimension increases 3 Elbows to Maximum Vertical V1 Minimum H1 Maximum HTotal V1 V2 MAXIMUM 6 ft 1 8 m 8 in 203 mm 3 ft 914 mm 19 ft 7...

Страница 20: ...r and attach with sheet metal screws 6 Push the flex pipe back up into the ceiling support box center the retro connector and attach it to the support box with sheet metal screws 7 The connection betw...

Страница 21: ...xhaust Section Included in Chimney Liner Termination Kit 4 ft 1m of 3 in 76mm Flex Liner Air Intake Section Included in Chimney Liner Termination Kit The chimney must be sealed from the 4 ft 1m sectio...

Страница 22: ...he hole is framed a wall thimble is required This allows the retro connector to mount directly on the masonry and provide the correct clearances to combustibles See Figure 4 18 4 To determine the leng...

Страница 23: ...Included in Masonry Chimney Conversion Kit Wall Thimble Cover Included in Masonry Chimney Conversion Kit Figure 4 20 8 Secure the top adapter to the flashing Use three sheet metal screws through the s...

Страница 24: ...of Fire Coaxial to colinear venting configuration may only be used in existing non combustible chimney Installation in any other venting application could cause fire CAUTION Do not use any flue restri...

Страница 25: ...ckness is greater than 7 5 8 in a DVP HSM B will be required SLP Pipe Shown 1 in 25 mm clearance bottom sides Heat Shield Wall Shield Firestop WALL Heat Shield Wall Shield Firestop WALL 3 in 76 mm top...

Страница 26: ...kept back from the pipe to prevent overheating D Install Attic Insulation Shield WARNING Fire Risk DO NOT allow loose materials or insulation to touch vent Hearth Home Technologies requires the use o...

Страница 27: ...Fire Failure to maintain air space clearance may cause overheating and fire Figure 6 1 1 Thread Allen bolts through nuts until flush NOTE Two Allen bolts and two nuts are included in the component ba...

Страница 28: ...securely fitted and locked into the preceding component Required Commercial Multi family Multi level exceeding two stories or High Rise Applications For Installation into a commercial multi family mul...

Страница 29: ...e Sections NOTICE If slip section is too long the inner and outer flues of the slip section can be cut to the desired length Apply a bead of silicone sealant 300 F minimum continuous exposure rating i...

Страница 30: ...fsets must be supported every 8 ft 2 44 m after the maximum allowed 25 ft 7 62 m of unsupported rise Vertical runs originating off the rear of the appliance or after any elbow must be supported every...

Страница 31: ...mark the outline of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3 mm l...

Страница 32: ...S MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 7 11 Minimum Height From Roof To Lowest Discharge Opening NOTICE Failure to properly caulk the roof flashing and pipe seams may...

Страница 33: ...nto Brackets Slide the assembled storm collar down the pipe section until it rests on the roof flashing Tighten nut and make sure the collar is tight against the pipe section Caulk around the top of t...

Страница 34: ...A minimum 1 1 2 in 38 mm overlap MUST be maintained Use an extended heat shield if the finished wall thickness is greater than 7 1 4 in 184 mm The extended heat shield may need to be cut to length ma...

Страница 35: ...he cap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223...

Страница 36: ...pplicable electrical codes when it is installed in locations such as in bathrooms or near sinks Low voltage and 110 120 VAC voltage cannot be shared within the same wall box WARNING Risk of Shock Plug...

Страница 37: ...1 5 AMP system Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4AA cell batteries not included into the battery pack before use NOTICE Batterie...

Страница 38: ...und wire At the switch box connect the black hot wire and red switch leg wire to the wall switch as shown At the appliance connect the black hot white neutral and green ground wires to the junction bo...

Страница 39: ...nce top and place it on a flat surface with the porcelain side up to prevent damage Remove the back shield by removing the two screws along the top of the shield See Figure 8 4 Place the blower on the...

Страница 40: ...res Use the blue jumper wire provided in the appliance component bag to make the connection on junction box terminals as shown in Figure 8 9 Push the speed control knob onto the stem Secure any extra...

Страница 41: ...he junction box 2 Plug the fan into the receptical on the auxiliary box 3 Connect the two white wires from the fans wiring harness together using the 2 inch male to male jumper wire supplied with the...

Страница 42: ...allations NOTICE If the heating value of the gas has been reduced these rules do not apply Check with your local gas utility or authorities having jurisdiction When installing above 2000 feet elevatio...

Страница 43: ...stallation The air shutter is set fully open at the factory for minimum vertical vent run Adjust air shutter for longer vertical runs See Figure 9 1 Loosen the wing nuts Slide the wing nut to the righ...

Страница 44: ...top casting from unit and set aside on prepared work surface See Figure 10 1 3 Remove front casting by grasping it at the top and sliding straight up Set aside on prepared work surface See Figure 10 1...

Страница 45: ...t out Place the notch in the Rear Log over the pilot assembly Push the log all the way to the rear of the firebox and center the log from left to right See Figure 10 3 LOG PLACEMENT INSTRUCTIONS Figur...

Страница 46: ...st Flue Restrictor The flue restrictor may need to be installed if there is a large amount of vertical pipe installed in the vent run Installation of the flue restrictor requires the removal of the ba...

Страница 47: ...9 1 4 in 235 mm SLP45 45 Elbow SLP90 90 Elbow Effective Height Length SLP PIPE SLP HVS Horizontal Pipe Support SLP FS Ceiling Firestop SLP WS Wall Shield Firestop 10 7 8 in 276 mm 8 7 8 in 225 mm 1 1...

Страница 48: ...The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is...

Страница 49: ...1 5 16 in 34 mm SLP DCF BK Ceiling Firestop Black 12 1 2 in 318 mm 12 in 305 mm SLP TVHW Vertical Termination Cap A Vent Components Diagrams continued Figure 11 3 SLP Series Vent Components SLP LPC SL...

Страница 50: ...on Manual 2345 983_R2 07 15 50 DV 46DVA GCL Coaxial Colinear Appliance Connector LINK DV30B Flex Liner Kit 768 380A Stainless Steel Flex Pipe COAXIAL to COLINEAR VENTING Figure 11 4 SLP Series Vent Co...

Страница 51: ...SLP48M 46 DVA 48 DL4 48 Pipe Length Black SLP48 BK 46 DVA 48B DL4B Adjustable Length 3 6 Black SLP6A B Adjustable Length 3 6 Galvanized SLP6AM Adjustable Length 3 7 Galvanized 46DVA 08A Adjustable Len...

Страница 52: ...P CCS BK 46DVA CS 4SS Ceiling Support 46DVA DC 4CS Co Axial to Co Lineal Appliance Connector 46DVA GCL CAA Decorative Ceiling Firestop Black SLP DCF BK 4TR Decorative Radius Cover DRC RADIUS Firestop...

Страница 53: ...ols and Wall Switches Follow the instructions supplied with the control installed to operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feat...

Отзывы: