background image

7039-174K

16

August 13, 2018

Discovery I

Appliance Set-Up

USA

Figure 16.2 - Floor Installation

A. Outside Air Kit Installation 

A source of air (oxygen) is necessary in order for 

combustion to take place.  Whatever combustion air is 

consumed by the fire must be replaced.  Air is replaced via 

air leakage around windows and under doors. In homes 

that have tightly sealed doors and windows, an outside air 

source is needed. An optional Outside Air Kit is available. 

Optional OAK-ACC includes: 

Termination cap, (2) wire ties, flex adapter, and fasteners

Items Needed for Installation (not supplied)

• 

4 inch flex aluminum pipe, or if using alternate material, 

then it shall be made from durable, non-combustible, 

heat resistant material up to 350oF.  Cut the pipe to the 

required length for your installation. 

• 

Phillips head screw driver 

• 

Silicone sealant

• 

Drills and saws necessary for cutting holes through the 

wall or flooring in your home.

Installation Instructions

1. 

Remove all materials from packing box.

2.  Floor & Rear Installation:

  Cut a 4 inch (102mm) hole 

in outside wall or floor to accommodate outside air 

piping.  Use 4 inch (102mm) aluminum metal flex or 

rigid piping to directly connect outside air to appliance 

intake.  Use the supplied termination cap with a rodent 

screen.  Seal between the wall (or floor) and the pipe 

with silicone to prevent moisture penetration. 

Figure 16.1 - Rear Installation

Fire Risk.

Asphyxiation Risk.

Do not draw outside combustion air from:

• 

Wall, floor or ceiling cavity

• 

Enclosed space such as an attic or garage

• 

Close proximity to exhaust vents or chimneys

Fumes or odor may result

WARNING

Asphyxiation Risk.

Outside air inlet must be located to prevent 

blockage from:

•  Leaves

• 

Snow or ice

• 

Other debris

Block may cause combustion air starvation

Smoke spillage may set off alarms or irritate 

sensitive individuals.

WARNING

Asphyxiation Risk.

Length of outside air supply duct shall NOT 

exceed the length of the vertical height of the 

exhaust flue.

• 

Fire will not burn properly

• 

Smoke spillage occurs when door is opened 

due to air starvation.

WARNING

Содержание DISCOVERY-I

Страница 1: ...votre revendeur ou visitez www quadrafire com If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void...

Страница 2: ... Materials 4 G Sleeping Room 4 H California Prop65 4 2 Getting Started 5 A Design and Installation Considerations 5 B Fire Safety 5 C Negative Pressure 5 D Tools And Supplies Needed 6 E Inspection of Appliance and Components 6 F Removal of Appliance from Shipping Materials 6 G Install Checklist 7 3 Dimensions and Clearances 8 A Appliance Dimensions 8 B Hearth Protection Requirements 9 C Clearances...

Страница 3: ... EPA emission test LHV assumes the moisture is already in a vapor state so there is no loss in energy to vaporize Weighted average HHV High Heating Value efficiency using Douglas Fir dimensional lumber and data collected during EPA emission test HHV includes the energy required to vaporize the water in the fuel A range of BTU outputs based on EPA Default Efficiency and the burn rates from the low ...

Страница 4: ...le and other interior components NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your dealer Installation...

Страница 5: ... chimney heights Ideal performance is with height of chimney between 14 16 feet 4 26 4 88m measured from the base of the appliance C Negative Pressure B Fire Safety To provide reasonable fire safety the following should be given serious consideration 1 Install at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and clo...

Страница 6: ...ppliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a...

Страница 7: ...liance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installtion is complete Comments Further description of the issues who is responsible Installer Builder Other Trades etc and corrective act...

Страница 8: ...e 8 1 Front View Figure 8 3 Side View 9 1 4 in 233mm 24 1 8 in 613mm 33 7 8 in 860mm 23 5 8 in 600mm 13 1 2 in 343mm 11 1 2 in 292mm 15 in 381mm Figure 8 2 Top View 11 7 8 in 300mm 6 3 4 in 170mm 3 1 2 in 89mm 3 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 6 inch 152mm diameter ID ...

Страница 9: ...exception WARNING Fire Risk Hearth pads must be installed exactly as specified High temperatures or hot embers may ignite concealed combustibles Corner hearth pad dimensions with single wall pipe Corner hearth pad dimensions with double wall pipe USA minimum flat wall hearth pad dimensions Canada flat wall hearth pad dimensions with double wall horizontal venting this dimension will vary depending...

Страница 10: ...E 12 1 2 318 5 1 2 140 24 1 2 622 13 330 7 1 2 191 19 483 43 1092 5 127 INSTALLATION ALCOVE DOUBLE WALL PIPE 12 1 2 318 5 1 2 140 24 1 2 622 13 1 2 343 N A N A 43 1092 5 127 For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney Maximum depth of Alcove shall be no more than 48 inches 1219mm and the ref...

Страница 11: ...ll through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures un...

Страница 12: ... Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 12 1 12 2 Must have an approved and Listed cap Must not be located where it will become plugged by snow or other material Must terminate at least 3 feet 91cm above the roof and at least 2 feet 61cm above any portion of the roof within 10 feet 305cm Must be located...

Страница 13: ...LC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installation D Chimney Height Rise and Run This product was designed for and tested on a 6 inch 152mm chimney 14 to 16 feet 420 480cm high includes appliance height measured from the base of the appliance The furth...

Страница 14: ...mended by chimney connector manufacturer Figure 14 2 Instructions 1 Open inside wall at proper height for the chimney connector to entry the masonry chimney Figure 14 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm outside dimension frame from 2 x 2 framing lu...

Страница 15: ...or Single wall connector or appliance pipe This must be at least 24 gauge mild steel or 26 gauge blue steel The sections must be attached to the appliance and to each other with the crimped male end pointing toward the appliance All joints including the connection at the flue collar should be secured with 3 sheet metal screws Make sure to follow the minimum clearances to combustibles Where passage...

Страница 16: ...llation Instructions 1 Remove all materials from packing box 2 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly connect outside air to appliance intake Use the supplied termination cap with a rodent screen Seal between the wall or floor and the pipe with silicone to prevent mo...

Страница 17: ... Removal 1 Remove solid panel from side by lifting up and pulling away from appliance use a flat tool to pry from bottom if needed Figure 17 4 NOTE 300 degree F high temp paint can be use to repaint the solid side panel only DO NOT use on the rest of appliance this requires 1200 degree F high temp paint Tile Panel Installation 2 Remove tile frame from side by lifting up and pulling away from appli...

Страница 18: ... bracket containing the snap disc and magnet under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Figure 18 2 MANUAL Overides the Snap Disc AUTO Fan will turn ON OFF Automatically by the Snap Disc Controls the Fan Speed Figure 18 1 Door Handle Fiber Handle C Door Handle Assembly 1 Install fiber handle to door handle rod Shock Risk Do...

Страница 19: ...oor protection requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure NOTE Offsets from the vertical not exceeding 45 are allowed per Section 905 a of the Uniform Mechanical Code UMC Offsets greater than 45 are considered horizontal and are also allowed providing th...

Страница 20: ...7039 174K 20 August 13 2018 Discovery I Date of Service Performed By Description of Service 7 Reference Materials A Service Maintenance Log ...

Страница 21: ...rs Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER ACCESSORIES Blower Assembly BK ACC Blower Control Box w Switch SRV7000 194 Y Blower Convection 812 4900 Y Component Pack SRV7033 051 Snap Disc Bracket Assembly SRV7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness Blower 7033 ...

Страница 22: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ ______...

Отзывы: