10
06/21
7022-801H
CASTILE INSERT
B. Clearance To Combustibles, UL and ULC
Figure 10.1
AS A BUILT-IN - Framing Dimensions
Be sure to follow vent manufacturers clearance to
combustibles.
*If interior of chase will be drywalled, add the thickness
to this measurement.
**From finished floor protection. The size of your floor
protector choice must be added to this dimension.
23 in - top vent**
(584mm)
23-1/2 in - rear vent**
(597mm)
23 in - top vent**
(584mm)
23-1/2 in - rear vent**
(597mm)
31-7/8 in.
(810mm)
16-7/8 in.*
(429mm)
NOTE:
•
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY
.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual
design preference.
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
WARNING