E. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass.
D. Mobile Home Approved
H. Sleeping Room
I. California - Prop65
•
This appliance is approved for mobile home
installations; when not installed in a sleeping room and
when an outside combustion air inlet is provided.
•
The structural integrity of the mobile home floor, ceiling,
and walls must be maintained.
•
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
chimney must be listed to UL103 HT or a listed UL-
1777 full length six inch (152mm) diameter liner must
be used.
•
Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation.
Hearth & Home Technologies WILL NOT warranty
appliances that exhibit evidence of over-firing. Evidence
of over-firing includes, but is not limited to:
•
Warped air tube
•
Deteriorated refractory brick retainers
•
Deteriorated baffle and other interior components
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
• Installation and use of any damaged appliance.
•
Modification of the appliance.
•
Installation other than as instructed by Hearth &
Home Technologies.
• Installation and/or use of any component part not
approved by Hearth & Home Technologies.
•
Operating appliance without fully assembling
all components.
• Operating appliance without legs attached (if
supplied with appliance).
•
Do NOT Over fire
- If appliance or chimney connector
glows, you are over firing.
Any such action that may cause a fire hazard.
WARNING
Fire Risk
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
WARNING
This product and the fuels used to operate this product (wood), and
the products of combustion of such fuels, can expose you to
chemicals including carbon black, which is known to the State of
California to cause cancer, and carbon monoxide, which is known to
the State of California to cause birth defects or other reproductive
harm. For more information go to: WWW.P65Warnings.ca.gov
F. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combination of the following:
- Steel
- Plaster
- Brick
- Iron
- Concrete
- Tile
- Glass
- Slate
Materials reported as passing
ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C
.
G. Combustible Materials
Material made of/or surfaced with any of the
following materials:
- Wood
- Compressed Paper
-
Plant Fibers
- Plastic
- Plywood/OSB
-
Sheet Rock (drywall)
Any material that can ignite and burn: flame proofed or not,
plastered or non-plastered.
NOTE:
Hearth & Home Technologies, manufacturer
of this appliance, reserves the right to alter
its products, their specifications and/or price
without notice.
When installed in a sleeping room it is recommended that
a smoke and/or CO alarm be installed in the bedroom. The
size of the room must be at least 50ft³ per 1,000 Btu/hr
stove input, if the stove exceeds the room size, outside air
must be installed.
Содержание 4300 Series
Страница 31: ...31 February 19 2020 7037 801B Date of Service Performed By Description of Service ...
Страница 32: ...32 February 19 2020 7037 801B Date of Service Performed By Description of Service ...
Страница 33: ...33 February 19 2020 7037 801B Date of Service Performed By Description of Service ...