background image

© 2022 Quadient®, Inc.            

       Page 

3

IJ-15K Modem to Adapter PCB Conversion Instructions

Required Tools:

T10 Torque Screwdriver

T20 Torque Screwdriver

#1 Phillips Screwdriver

1. Power off the IJ-15K base

2. Open the Top Cover

Содержание IJ-15K

Страница 1: ...Franking Machine Installation Guide IJ 15K...

Страница 2: ...Table of Contents IJ 15K Modem to Adapter PCB Conversion Instructions 3 Connect Box IJ 15K Setup 7 IJ 15K Credit Procedure with new Adapter PCB 13 Page 1...

Страница 3: ......

Страница 4: ...Quadient Inc Page 3 IJ 15K Modem to Adapter PCB Conversion Instructions Required Tools T10 Torque Screwdriver T20 Torque Screwdriver 1 Phillips Screwdriver 1 Power off the IJ 15K base 2 Open the Top...

Страница 5: ...Top Cover 4 screws using a T10 Torque screwdriver 4 Remove the Right Side Cover 2 screws in the rear using a T20 Torque screwdriver 5 Remove the Right Side Plate 3 screws 2 rear 1 side using a T20 Tor...

Страница 6: ...2 screws using a 1 Phillips screwdriver 8 Install the new Adapter PCB 2 screws from the previous step using a 1 Phillips screwdriver 9 Plugin the new Adapter PCB 10 Install the Right Side Plate 3 scre...

Страница 7: ...2022 Quadient Inc Page 11 Install the Right Side Cover 2 screws in the rear using a T20 Torque screwdriver 12 Install the Top Cover 3 screws using a T10 Torque screwdriver 13 Close the Top Cover...

Страница 8: ...Classification EXTERNAL 2022 Quadient Inc Connect Box IJ 15K Setup Author Jean Maurice Sanon Valid from 12 14 2022 Version No V1 0 Page 7...

Страница 9: ...ification EXTERNAL Document name Connect Box IJ 15K Setup 2022 Quadient Inc Page Change Control Modification Notice Author Date Version Changes Highlight Initial Document Jean Maurice Sanon 12 14 2022...

Страница 10: ...2 encryption and securing of data Upon connecting the Connect Box to the customer s Wi Fi network and properly configuring the Mailing System any communication originating from the Mailing System will...

Страница 11: ...ect the desired network and click Connect Enter the password and click Connect Click OK to validate 4 Adding the URLs The URLs will need to be added to the Connect Box To do so navigate to the SETTING...

Страница 12: ...15K Setup 2022 Quadient Inc Page The URLs will also need to be added to the IS IN IX screen It is also located under the SETTINGS tab Connect the IJ 15K to the connect Box Connect the USB A to the Co...

Страница 13: ...SB B Core System CPU NXP i MX6UL 528MHz ARM Cortex A7 up to 1GB DDR3L Power Specification Power Connector 5 5 2 1mm barrel jack External Power Supply 5V DC 5 1 2A Safety UL CUL CB GS CE FCC Wireless Q...

Страница 14: ...2022 Quadient Inc Page 1 IJ 15K Credit Procedure with new Adapter PCB 1 Main Menu 2 Select Postal Services 2 3 Select Credit 1...

Страница 15: ...2022 Quadient Inc Page 4 Enter New Value a whole dollar amount 5 Confirm Amount select OK 6 Credit INFO Please wait...

Страница 16: ...2022 Quadient Inc Page 7 INFO Please wait 8 INFO Modem initialization running 9 INFO Modem Detection Step 1 3...

Страница 17: ...2022 Quadient Inc Page 16 10 INFO Modem Detection Step 2 3 11 INFO Modem Detection Step 3 3 12 ERROR M254 No answer...

Страница 18: ...2022 Quadient Inc Page 17 13 ERROR M324 Device fails to connect 14 Wait 30 seconds then try again Select Credit 1 15 INFO Previous transaction failed...

Страница 19: ...2022 Quadient Inc Page 18 16 INFO Please wait 17 INFO Modem initialization running 18 INFO Modem Detection Step 1 3...

Страница 20: ...2022 Quadient Inc Page 19 19 INFO Modem Detection Step 2 3 20 INFO Modem Detection Step 3 3 21 INFO connecting to server...

Страница 21: ...2022 Quadient Inc Page 20 22 INFO Transaction in progress 23 INFO Transaction successful A0161300 A 07 06 2023...

Страница 22: ...A0161300 A 07 06 2023...

Отзывы: