background image

 

160.459UK User Manual

 

 
TIMER CONTROLLER 
 

The timer controller can be used to control the HZ-3 remotely. 
Please note Fan Speed (FS) and Haze Output (HO) must be set to zero for the remote timer 
controller to operate. 

 

 

 

1.

 

Timer on/off button 

2.

 

Continuous output 

3.

 

Manual override button 

4.

 

Timer LED indicator (Illuminated Yellow when timer active) 

5.

 

Manual ready indicator (Illuminates Green when ready) 

6.

 

Power indicator (Illuminates red when power is on) 

7.

 

Adjust the amount of Haze released (between 0 

 100%) 

NOTE

The below controls are only used when in timer mode

 

8.

 

Adjust the interval gap between each release of Haze (between 0 

 30 Min 

approximately) 

9.

 

Adjust the duration the Haze / Haze is released at each interval (between 0 

 15 

seconds approximately) 
F

or best results select “continuous” and adjust output to achieve desired effect, note it 

can take around 30 seconds for the machine to produce the correct output. 

 

Содержание 160.459UK

Страница 1: ...160 459UK User Manual HZ 3 HAZE MACHINE Order ref 160 459UK User Manual VERSION 1 2...

Страница 2: ...k is removable and easy to clean There is a fluid level sensor which indicates when the machine needs refilling so as not to damage the pump This product has been specifically developed for profession...

Страница 3: ...se contact your local dealer at once Do not try to fix this item yourself or you will lose the warranty Please keep the original package and invoice for any possible replacement or returned demand REC...

Страница 4: ...TAL ELECTRICAL RISK AND LONG LIFE OPERATION For your safety please kindly pay attention to all of the warnings listed below Always plug in the power plug last and disconnect from the mains when the de...

Страница 5: ...older above the IEC Socket to reveal the fuse Replace the correct fuse rating as stated on lighting or user guide Then lock the fuse holder cover back into place GENERAL MAINTENANCE To maintain optimu...

Страница 6: ...al LAYOUT HZ 3 1 Mounting Handle 2 Carry handle 3 Adjustable output flap 4 Haze nozzle output 5 Removable bottle 6 Thumb screw for mounting bracket 7 Thumb screw for adjustable out put flap 8 Handheld...

Страница 7: ...160 459UK User Manual REAR PANEL HZ 3 1 Remote connection 2 Power IN Use IEC lead provided 3 LED Digital controller see next section 4 DMX Out 5 DMX IN...

Страница 8: ...p and down keys to set the secondary function Display Function HEAt Unit is warming up no function available A001 A512 DMX address FS 1 to 5 Manual Fan Speed 1 slow 5 high HO 0 to 5 Manual Haze output...

Страница 9: ...dy indicator Illuminates Green when ready 6 Power indicator Illuminates red when power is on 7 Adjust the amount of Haze released between 0 100 NOTE The below controls are only used when in timer mode...

Страница 10: ...User Manual TECHNICAL SPECIFICATION Power supply 230Vac 50Hz Fuse F5A Power 700W Re heat time 3 min approx Haze Output 2 400 Cu Ft 68m per minute Tank capacity 1 6 Litres Dimensions 310 x 330 x 263mm...