background image

 

 

HARDWARE INSTALLATION AND REFERENCE GUIDE 

 
 

 

 

www.qtech.ru 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QSW-4600-12T-POE Switch 

Hardware Installation and Reference Guide V1.0

 

 

Содержание QSW-4600-12T-POE

Страница 1: ...HARDWARE INSTALLATION AND REFERENCE GUIDE www qtech ru QSW 4600 12T POE Switch Hardware Installation and Reference Guide V1 0...

Страница 2: ...or any portion of this document in any form or by any means without the prior written consent of QTECH is prohibited Exemption Statement This document is provided as is The contents of this document...

Страница 3: ...he same time it is assumed that the users are already familiar with the related terms and concepts Obtaining Technical Assistance QTECH Website http www qtech ru Technical Support https helpdesk qtech...

Страница 4: ...service network residential broadband access and business building network providing high speed high efficiency secure and intelligent access solutions Table 1 1 QSW 4600 Model 10 100 1000 Base T Auto...

Страница 5: ...Rated current 2A EEE Supported PoE Ports 1 8 are PoE capable with the maximum power output of 30W The maximum output power of PoE PoE is 125W PoE ports support IEEE 802 af at PoE The available number...

Страница 6: ...he QSW 4600 12T Ethernet switch provides 10 10 100 1000Base T Ethernet ports 2 SFP ports and 1 Console port On the back panel it provides AC power ports Front Panel Figure 1 1 Front Panel of QSW 4600...

Страница 7: ...Frequency range 50 60 Hz Rated current 2A Power cord specification 10A Heat Dissipation The QSW 4600 12T POE adopts fanless design thereby ensuring normal function of the device in the specified envi...

Страница 8: ...tification State Meaning System status LED Status Off The switch is not receiving power Blinking green The system is being initialized Continuous blinking indicates errors Solid green The switch is op...

Страница 9: ...een The port is receiving or transmitting traffic at 1000 Mbps Solid yellow The port is connected at 10 100 Mbps Blinking yellow The port is receiving or transmitting traffic at 10 100 Mbps RJ45 port...

Страница 10: ...ack Before moving the device turn off all power supplies and dismantle all power modules 2 1 3 Electricity Observe local regulations and specifications when performing electric operations Relevant ope...

Страница 11: ...ents The machine room should be at least 5km away from the heavy pollution source such as the smelter coal mine and thermal power plant 3 7km away from the medium pollution source such as the chemical...

Страница 12: ...ent space at least 10 cm distances from both sides and the back plane of the cabinet should be reserved at the ventilation openings to ensure the normal ventilation After various cables have been conn...

Страница 13: ...seful life of the equipment but also causing communication faults Table 2 2 shows the requirements for the dust content and granularity in the equipment room Table 2 2 Requirements for the Dust Conten...

Страница 14: ...ng if not they should use a protective grounding wire to connect the grounding end of the A C socket to the building s protection location The power supply socket must be installed in a place that is...

Страница 15: ...a completely electrically isolated unit Conducted interference results from the electromagnetic wire or signal cable connection between the source and the sensitive component along which cable the int...

Страница 16: ...QSW 4600 Series Switch Hardware Installation and Reference Guide 16 www qtech ru Meters Multimeter The tool kit is customer supplied...

Страница 17: ...her the requirements of electrical current are met Whether related network adaption lines are already laid out 3 3 Installing the QSW 4600 Precautions During installation note the following points Con...

Страница 18: ...ution cabinets Attach the mounting brackets to the switch with the supplied screws as shown in Figure 3 1 Figure 3 1 Attaching the Mounting Bracket to the Switch Align the mounting holes in the mounti...

Страница 19: ...curely attach the mounting brackets on the wall as shown in Figure 3 5 Figure 3 2 Attaching the Switch on the Wall 3 3 3 Mounting the Switch on a Table Attach the four rubber feet to the recessed area...

Страница 20: ...the installation switch off the power supply so as to avoid any personal injury or damage to the component due to connection errors Check that the ground line is connected Check that the cables and po...

Страница 21: ...cable with DB 9 jack to the serial port of the PC Step 2 Connect the end of the console cable with RJ45 to the console port of the switch Setting HeperTerminal Parameters Step 1 Start the PC and run t...

Страница 22: ...K the interface as shown in figure 4 3 is displayed Choose the serial port used currently in the column use when connecting Figure 4 3 4 After choosing the serial port click OK to display the serial p...

Страница 23: ...correctly connected The power supply voltage complies with the requirement of the switch The control cable of the PC is properly connected to the console port of the switch The HyperTerminal is start...

Страница 24: ...qtech ru Check whether the status of the switch indicator is normal Check whether the main program of the device is normally loaded Check whether the time on the device is consistent with the current...

Страница 25: ...e contact Check whether the power socket at the equipment room is normal and whether the power cable of the switch is in good contact The status indicator is red Fan alarm Temperature alarm Power alar...

Страница 26: ...connected The Rx and Tx ends are connected reversely The interconnected optical module type does not match The fiber type is not correct The length of the optical fiber exceeds that rated of the optic...

Страница 27: ...uses four pairs of wires for transmission all of which must be connected Figure A 1 shows the connections of the twisted pairs used by the 1000BASE T port Figure A 1 Four Twisted Pairs of the 1000BASE...

Страница 28: ...8 www qtech ru Optical Fiber Connection For the optical fiber ports select single mode or multiple mode optical fibers for connection according to the fiber module connected The connection schematic d...

Страница 29: ...tical requirement Precautions for installation Make sure that the PE terminal of the power arrester has been well grounded After connecting the switch AC power plug to the socket of the power arrester...

Страница 30: ...he grounding line to the grounding terminal of the switch 3 Use the multimeter to check whether the grounding line for the arrester is in good contact with the switch grounding terminal and the framew...

Страница 31: ...k cable to the IN end and connect the switch Ethernet port to the OUT end Poor arrester grounding The length of the grounding line should be as short as possible to ensure that it is in good contact w...

Страница 32: ...t often bend or suffer removal insertion should be greater than seven times their respective diameters The bend radius of a common coaxial cable should be greater than seven times its diameter The ben...

Страница 33: ...ables should maintain a space equal to or greater than 30 mm The binding rack and cabling slot inside and outside the cabinet should be smooth without sharp corners The metal hole traversed by cables...

Страница 34: ...should be folded and placed in a proper position of the cabinet or cabling slot The proper position indicates a position that will not affect device running or cause device damage or cable damage dur...

Страница 35: ...Cable Fastening The hard power cable should be fastened by the terminal connection area to prevent stress Do not use self tapping screws to fasten terminals Power cables of the same type and in the sa...

Страница 36: ...uide 36 www qtech ru No knot is allowed in cabling or bundling For solder less terminal blocks such as air switches of the cold pressing terminal type the metal part of the cold pressing terminal shou...