System Settings
81
TIP:
After enabling the licenses, the functions cannot be disabled and these
license options will be hidden.
6.5.3.
Firmware Synchronization
Select the
Firmware Synchronization
function tab in the
Maintenance
function submenu to
be used on dual controller systems to synchronize the controller firmware versions when
the firmware of the master controller and the slave controller are different. The firmware of
slave controller is always changed to match the firmware of the master controller. It doesn’t
matter if the firmware version of slave controller is newer or older than that of the master.
Normally, the firmware versions in both controllers are the same.
Figure 6-17
Both Firmware Versions are Synchronized
If the firmware versions between two controllers are different, it will display the warning
message. Click the
Apply
button to synchronize and force a reboot.
TIP:
This tab is only visible when the dual controllers are installed. A single
controller system does not have this option.
6.5.4.
System Identification
Select the
System Identification
function tab in the
Maintenance
function submenu to turn
on or turn off the UID (Unique Identifier) LED control mechanism. The system UID LED helps
users to easily identify the system location within the rack.
When the UID LEDs are turn off, click the
OK
button to turn on the UID LEDs which are light
blue
color, located on the right panel of front view and both controllers of rear view.
Содержание XCubeSAN XS5224D
Страница 71: ...SANOS User Interface 49 nnnnn RPM Power Supply Local PSU n status Reset to Default Yes No...
Страница 99: ...System Settings 77 Figure 6 14 System Information...
Страница 315: ...Monitoring 293 Figure 13 5 Hardware Monitoring...
Страница 327: ...Support and Other Resources 305 Figure 15 1 Download Service Package in the SANOS UI...
Страница 331: ...Support and Other Resources 309...