System Components Overview
19
11
10GbE iSCSI
(RJ45)
Port 2
12
12Gb/s SAS Wide Port 1
(SFF8644)
13
12Gb/s SAS Wide Port 2
(SFF8644)
INFORMATION:
7
Console cable (NULL modem cable) to connect from console port of the
storage system to a RS 232 port on the management PC. The console
settings are on the following: Baud rate: 115,200, 8 data bit, no parity, 1
stop bit, and no flow control; terminal Type: vt100.
8
XCubeSAN series supports traditional UPS via a serial port and network
UPS via SNMP. If using the UPS with a serial port, connect the system to
the UPS via the included cable for communication. (The cable plugs into
the serial cable that comes with the UPS.) Then set up the shutdown
values for when the power goes out.
For a greater understanding of the related color and the behavior of the controller module,
please refer to the chapter 5.2,
section in the Descriptions of LEDs and Buttons
chapter.
2.5.
Power Supply Unit
All XCubeSAN series models are equipped with two redundant and hot swappable PSUs
(Power Supply Units). The PSU for 3U/4U systems and 2U systems are the same, but the
installation direction is different. (If you pull out the PSU from the system chassis, for 4U/3U
system, the sticker on the PSU will be at down side; for 2U system, the sticker will be at right
side).The images and the table below illustrate the location of PSU in the LFF or SFF system.
Содержание XCubeSAN XS5224D
Страница 10: ...viii Copyright 2017 QSAN Technology Inc All Right Reserved Appendix 114 End User License Agreement EULA 114...
Страница 121: ...Quick Maintenance 103 Figure 6 21 Example of a Failed Power Module Figure 6 22 Example of a Failed Flash Module...
Страница 125: ...Support and Other Resources 107 Figure 7 1 Download Service Package in the SANOS UI...
Страница 129: ...Support and Other Resources 111...