XCubeFAS 3126
Hardware Manual
System Components Overview
© 2021 QSAN Technology, Inc. All rights reserved.
www.qsan.com
Official
Document
11
9
Reset to Factory Default Button
3
10
Host Card Slot 2
(host card is an optional part)
1
Console cable (NULL modem cable) connects from console port of the storage system to a RS 232 port on the
management PC. The console settings are on the following: Baud rate: 115,200, 8 data bit, no parity, 1 stop bit,
and no flow control; terminal Type: vt100.
2
XCubeFAS series supports traditional UPS via a serial port and network UPS via SNMP. If using the UPS with a
serial port, connect the system to the UPS via the included cable for communication. (The cable plugs into the
serial cable that comes with the UPS.) Then set up the shutdown values for when the power goes out.
3
Press the button for 3 seconds to progress reset to defaults and force a reboot. The default settings are:
Reset
Management Port
IP address to DHCP, and then fix IP address: 169.254.1.234/16.
Reset admin’s
Password
to 1234.
Reset
System Name
to model name plus the last 6 digits of serial number. For example: XF2026-123456.
Reset IP addresses of all
iSCSI Ports
to 192.168.1.1, 192.168.2.1,
…
etc.
Reset link speed of all
Fibre Channel Ports
to Automatic.
Clear all access control settings of the host connectivity.
Please refer to the following for the definition of LED behavior.
Figure 2-6 Controller LEDs
Table 2-5 Descriptions of Controller LEDs
NUMBER
DESCRIPTION
DEFINITION
1
10GbE iSCSI (SFP+) Port
Access LED
Blinking
Green
: Asserted when the link is
established, and packets are being
transmitted along with any receive activity
(Access).