PROGRAMMING
INSTALLER/DEALER SETTINGS
* Additional options available
only through the Dealer Code.
FIND IT
INSTALLER/DEALER
SETTINGS
Swipe down
for access
INSTALLATION
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
Setting
Default
Description
Account Number
blank
Security provider account number (up to 10 characters)
Power Management
Enabled
An energy-saving function when running on battery power only
SIA Power Restoration
Disabled
Turn on or off sensor hold for 60 seconds during power restore
Loss of Supervisory
Signals for Emergency
Sensors
4
Select the length in hours (4,12,24) before reporting a loss of
supervision on life safety devices.
NOTE:
For UL/cUL the wireless
supervision window for Emergency sensors (Smoke, Heat & CO
Detectors) shall be set to 4h
Loss of Supervisory
Signals forZ-Wave
4
Select the length in hours (4/24hrs) before reporting a loss of
supervision on Z-Wave Sirens.
Loss of Supervisory
Signals for Non
Emergency Sensors
24
Select the length in hours (4,12,24) before reporting a loss of
supervision on security devices
Installer/Dealer Settings
Change panel settings like supervisory times, power and cell loss timeout and
SIA settings.